OPERATING HEATER
Optional Remote Operation (Cont.)
INSPECTING BURNERS
Pilot Flame Pattern
Main Burner
WIRING DIAGRAM
OPERATING HEATER
Continued
CGHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on the
•In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.
•In the AUTO mode, the thermostat in the
IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immedi- ately to the temperature setting being turned up or down. IMPORTANT: The
INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 36 shows a correct pilot flame pattern. Figure 37 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down.If pilot flame pattern is incorrect, as shown in Figure 37
•turn heater off (see To Turn Off Gas to Appliance, page 17)
•see Troubleshooting, pages 20 through 22
Note: The pilot flame on natural gas units will have a slight curve, but the flame should be blue and have no yellow or orange color.
Pilot Burner | Pilot Burner |
Propane/LP Gas | Natural Gas |
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the con- trol knob on the heater to the OFF position.
Flame Adjustment | Control Knob |
Knob | in On Position |
Figure 36 - Correct Pilot Flame Pattern
Pilot Burner | Pilot Burner |
|
IH |
|
| IL | |
ON |
| F | P | O |
| O |
|
| T |
OFF |
|
| O | |
|
|
| ||
|
|
| N | |
REMOTE |
|
|
| |
|
|
|
| |
LO |
|
|
|
|
Selector Switch in Remote Position
Figure 34 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
Thermocouple | Natural Gas | |
Propane/LP Gas | ||
| ||
Figure 37 - Incorrect Pilot Flame Pattern |
|
MAIN BURNER
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or
Shows Temperature Setting
Increases Room
Temperature in
AUTO Mode
rust, with no flame present. If so, turn off heater and let cool. Remove blockage, blocked burner flame holes will create soot.
WIRING DIAGRAM
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
Decreases Room
Temperature in
AUTO Mode
Turns Burner On or Off and Allows You to Choose the Auto Setting
On
Off Receiver
Remote
Black
Red
TPTH TH
Gas Control
TPTH TP