Desa CCL3930NRA, CCL3018NRA Installing Wireless Remote Control Accessory, Installation, Continued

Page 14
INSTALLING WIRELESS REMOTE CONTROL ACCESSORY

14

INSTALLATION

Installing Wireless Remote Control Accessory

Installing Logs (Models CCL3018PR, CCL3018NR, CCL3924PR, CCL3924NR,

CCL3930PR, AND CCL3930NR)

INSTALLATION

Continued

INSTALLING WIRELESS REMOTE CONTROL ACCESSORY

Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1.Locate back of receiver under front burner of heater.

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

INSTALLING LOGS (CCL3018PR/PRA, CCL3018NR/NRA, CCL3924PR/PRA, CCL3924NR/NRA, CCL3930PR/PRA, AND CCL3930NR/NRA)

Installing 9-Volt Battery in Receiver WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Manual backgroundCAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to HI, check to see if flames contact any log. If so, reposition logs accord- ing to the log installation instructions in this manual. Flames contacting logs will create soot.

Receiver

Terminal

9-Volt

Battery Clip Wires

Battery

 

Figure 21 - Installing Receiver on the Back of the Base

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place the front log (#1) on the grate fingers. Make sure the front log rests firmly between the grate fingers and the grate base (see Figure 24).

Installing 9-Volt Battery (Not Included) in Hand- Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery. Place battery into the bat- tery housing.

3.Replace battery cover onto remote control unit.

2.Place the base of the middle log (#2) in the U-shaped slots of the grate base. The cutout on the right of the middle log should fit over the burner (see Figure 25). Make sure the front of the middle log is resting on the tabs of the grate base.

Front Log (#1)

Terminal Wires

9-Volt Battery

Battery Cover

Manual backgroundRemote

Control

Battery Unit

Housing

Grate

Fingers

Manual background Grate Base

Figure 24 - Installing Front Log (#1) (CCL3930PR/NR Shown)

Figure 22 - Installing Battery in Hand-Held Remote Control Unit

Manual background Remote

Control

Unit

Figure 23 - Installing Battery in Hand-Held Remote Control Unit (GHRCTA Series)

Middle Log (#2)

Burner

Tab

U-Shaped Slot

Figure 25 - Installing Middle Log (#2) (CCL3930PR/NR Shown)

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundvisitManual backgroundManual background.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111161-01A

Image 14
Contents WHAT TO DO IF YOU SMELL GAS UNVENTED VENT-FREE GAS LOG HEATERNot Used With Hand-HeldThermostat Remote Do not try to light any applianceWARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION PRODUCT IDENTIFICATIONContinued SAFETY PILOT PRODUCT FEATURESREMOTE CONTROL ACCESSORIES See Accessories, pageConfined Space and Unconfined Space DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONUnusually Tight Construction AIR FOR COMBUSTION AND VENTILATIONVentilation Air From Outdoors VENTILATION AIRVentilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONMINIMUM FIREPLACE CLEARANCE TO INSTALLATIONCHECK GAS TYPE COMBUSTIBLE MATERIALSContinued Minimum Noncombustible Material ClearancesINSTALLATION Between 8 and 12, above. IfDetermining Minimum Mantel Clearances MANTEL CLEARANCESFLOOR CLEARANCES INSTALLATIONContinued INSTALLING HEATER BASE ASSEMBLYINSTALLATION ChimneyINSTALLATION CONNECTING TO GAS SUPPLYInstallation Items Needed Installation Items NeededINSTALLATION Pressure Testing gas Supply Piping systemCHECKING GAS CONNECTIONS ContinuedINSTALLATION INSTALLING REMOTE RECEIVER UNITPressure Testing Heater Gas Connections ContinuedINSTALLATION INSTALLING WIRELESS REMOTE CONTROL ACCESSORYInstalling 9-VoltBattery in Receiver ContinuedContinued INSTALLATIONINSTALLATION LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING HEATER OPTIONAL REMOTE OPERATION MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE Shutting Off HeaterPILOT FLAME PATTERN WIRING DIAGRAMINSPECTING BURNERS MAIN BURNERMAIN BURNER CLEANING AND MAINTENANCELOGS POSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYTROUBLESHOOTING Maintenance, pageRefer to Air for Combustion and Venti OBSERVED PROBLEMOBSERVED PROBLEM ing Gas Connections, pages 12 andTROUBLESHOOTING Maintenance, pageTECHNICAL SERVICE SPECIFICATIONSSERVICE HINTS REPLACEMENT PARTSCCL3018NR, CCL3018NRA ILLUSTRATED PARTS BREAKDOWNMODELS CCL3018PR, CCL3018PRA ILLUSTRATED PARTS BREAKDOWNPART NUMBER PARTS LISTPARTS LIST CCL3018PRCCL3930PR, CCL3930PRA MODELSCCL3924PR, CCL3924PRA CCL3924NR, CCL3924NRA CCL3930NR, CCL3930NRAPARTS LIST PART NUMBEREQUIPMENT SHUTOFF VALVE GA5010 ACCESSORIESPARTS CENTRAL FIREPLACE HOODOWNERS REGISTRATION FORM TAPE Postage RequiredTAPE Page NOT A UPC WARRANTY INFORMATIONLIMITED WARRANTY COMFORT GLOW VENT-FREEGAS LOG HEATERS