Desa CGB3924NRA Installing Wireless Remote Control Accessory, Installing Logs CGD3924NRA

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

INSTALLING WIRELESS REMOTE CONTROL ACCESSORY

Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1.Locate back of receiver under front burner of heater.

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 19 - Installing Receiver on the Back of the Base

Installing 9-Volt Battery (Not

Included) in Hand-Held Remote

Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to the battery. Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery Cover

Terminal

Wires

 

Remote

 

Control

9-Volt

Unit

Battery Housing

Battery

Figure 20 - Installing Battery in Hand- Held Remote Control Unit

INSTALLING LOGS (CGD3924NRA)

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to HIGH, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 21).

2.Place the base of the middle log (#2) in the U-shaped slots of the grate base in front of the back log. The cutout on the right of the middle log should fit over the burner (see Figure 22). Make sure the front of the middle log is resting on the tabs of the grate base and the cutout area is centered over the burner “U” bend.

3.Locate the recesses on the back of the front log (#3). Fit these recesses between the posts of the grate base (see Figure 23).

Back Log (#1)

Peg

Hole in

Grate Base

Burner

Figure 21 - Installing Back Log (#1)

Middle Log (#2)

Tab

Burner

Cutout

“U” Bend

U-Shaped

Slot

Figure 22 - Installing Middle Log (#2)

Front Log (#3)

Recess

Post

Post

Figure 23 - Installing Front Log (#3)

Continued

105677

13

Image 13
Contents What to do if YOU Smell GAS Remote ReadyUnvented Natural GAS LOG Heater Safety Information Remote Control Accessories Product FeaturesProduct Identification Local CodesUnusually Tight Construction Providing Adequate VentilationConfined Space and Unconfined Space Determining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationMinimum Fireplace Clearance to Combustible Materials LOG Sizing RequirementsMinimum Noncombustible Material Clearances Unvented Natural GAS LOG Heater InstallationMantel Clearances Determining Minimum Mantel Clearances When Using a HoodFloor Clearances Determining Minimum Mantel ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Attaching Flexible Gas Hose to Heater Connecting to GAS SupplyChecking GAS Connections Installing Remote RE- Ceiver UnitInstalling Logs CGD3924NRA Installing Wireless Remote Control AccessoryInstalling 9-Volt Battery in Receiver Tered over the burner U bend Installing Logs on Models CGB3924PRA and CGB3930PRAOperating Heater For Your Safety Read Before LightingLighting Instructions Unvented Natural GAS LOG Heater Operating Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Remote OperationPilot Flame Pattern Inspecting BurnersMain Burner Service Hints Unvented Natural GAS LOG Heater Cleaning and MaintenanceTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Unvented Natural GAS LOG Heater TroubleshootingGas leak. See Warning statement at CGD3924NRA Unvented Natural GAS LOG Heater Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListCGB3924NRA CGB3930NRA KEY CGB3924NRA CGB3930NRA Part Number Description QTY Parts Under Warranty Unvented Natural GAS LOG Heater Replacement PartsParts not Under Warranty Parts CentralSpecifications AccessoriesWiring Diagram Warranty Information