Desa MSVFBP installation manual Installing Optional Wall Mounted Thermostat GWMT1

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Unscrew back panel on the stove and remove the log set from heater base. This will give you access to the valve.

2.Disconnect from the valve the wires running from the ON/OFF switch.

3.Run the wires from the wall thermo- stat through the rectangular cut-out in the back of the heater base. Connect one terminal of the wire for the wall ther- mostat to the THTP terminal on the valve. Connect remaining wire termi- nal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 23. If wires are not connected as shown the thermostat will not work.

4.Route the wire to a convenient loca- tion to mount your thermostat (no out- side wall). IMPORTANT: The wire must not exceed 25 feet in length.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sun- light, fireplace, or heat and air condi- tioning ducts.

To Remote

Accessory

Figure 23- Control Valve Terminals

5.Gently remove the cover of the ther- mostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

6.Feed the electrical wires through the rectangular slots (from the back) on each side of the base (see Figure 24).

WARNING: Do not connect this thermostat to a power source. Electrical shock and/or fire hazard will occur.

7.Connect one bare wire end to each ter- minal (“W” and “R”) of the thermostat base (see Figure 25).

8.Install the base to the wall with screws provided with thermostat.

9.Move the temperature adjustment back and forth to insure the bi-metal is free from restrictions.

10.Replace the cover onto the base. (Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.)

11.Set the temperature adjustment to the desired setting. This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.

Feed wires through rectangular slots

Figure 24 - Back View of Thermostat Base

Terminal “W”

W

Terminal “R”

R

Figure 25 - Thermostat Base Terminal “W” and “R”

INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL

Follow all installation instructions included with the GHRC Series and GHRCT Series wireless hand-held remote control kits (see Accessories, page 23).

105986

13

For more information, visit www.desatech.com

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSUN Valley Stove Company Safety InformationProduct Identification Product FeaturesLocal Codes Providing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsClearances to Combustibles InstallationCheck GAS Type Vent-Free Operation OnlyLift off corrugated box enclosing stove body crating Stove Cavity AssemblyAttaching Stove Legs Fastening Heater Base to Stove Drop Bottom Installing GAS LOG Heater Into StoveInstallation Items Needed Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Optional Wireless HAND-HELD Remote Control Installing Optional Wall Mounted Thermostat GWMT1Operating Heater For Your Safety Read Before LightingLighting Instructions Msvfbpr REMOTE-READY Models To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Variable Control Operation Lighting Instructions Msvfbp Variable MANUAL-CONTROL ModelsPilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Transporting StoveObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Top Technical Service Specifications Service Hints ReplacementWiring Diagram PartsAccessories Msvfbpr Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListMsvfbp KEY Part Description QTY SUN Valley Stove MC* Series Indicates Color Suffix Designation SUN Valley Stove Mchp Series Hepplewhite Stove Design Hepplewhite Stove Design SUN Valley Stove Mchp SeriesInternational Warranty Information