OWNER’S MANUAL
OPERATING
HEATER
Continued
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one of the following:
1.Turn control knob clockwise to the PILOT position.
2.Use remote control manual OFF button.
3.Set selector switch in the OFF position.
For wall thermostat operation, follow in- struction supplied with thermostat acces- sory GWMT1. For wall switch operation follow instructions supplied with GWMS2.
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. Note: The burners may light if
IMPORTANT: Be sure to press the ON/OFF buttons on the
IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery.
GHRC Series Operation:
2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.
GHRCT Series Operation:
2b. Press the AUTO/ON/OFF button on the
•In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 6 under Light- ing Instructions, page 14.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, page 14.
Flame Adjustment Knob |
|
|
|
|
|
|
|
| Control Knob in |
IH |
|
| PIL | On Position |
ON |
| F | O |
|
| O |
| T |
|
OFF |
| O |
| |
|
| N |
| |
REMOTE |
|
|
|
|
LO |
|
|
|
|
Selector Switch in Remote Position (Optional Remote Control)
Figure 28 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
OPTIONAL REMOTE
OPERATION
Note: All remote control accessories must be purchased separately (see Accessories, page 23). Follow instructions included with the remote control.
Thermostat Control Operation
(Optional GHRCT Only) The thermo- stat control setting on the remote control unit can be set to any comfort level be- tween WARMER and COOLER. The
Shows Temperature Setting
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
Increases Room
Temperature in AUTO
Mode
Decreases Room
Temperature in AUTO
Mode
Turns Burners On or Off and Allows You to Choose the Auto Setting
burners will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
Figure 29 - Thermostat Hand-Held Remote Control Unit Selections (GHRCT Series Only)
Continued
105986 | 15 | For more information, visit www.desatech.com |