SUN VALLEY STOVE COMPANY
VENT-FREE PROPANE/LP GAS STOVE HEATER
TROUBLESHOOTING
Continued
| OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | |||
| Delayed ignition burner | 1. | Manifold pressure is too low | 1. | Contact local propane/LP gas company | |
|
| 2. | Burner orifice clogged | 2. | Clean burner (see Cleaning and Mainte- | |
|
|
|
|
| nance, page 18) or replace burner orifice | |
|
|
|
|
|
|
|
| Burner backfiring during combustion | 1. | Burner orifice is clogged or damaged | 1. | Clean burner (see Cleaning and Mainte- | |
|
|
|
|
| nance, page 18) or replace burner orifice | |
|
| 2. | Damaged burner | 2. | Replace damaged burner | |
|
| 3. | Gas regulator defective | 3. | Replace gas control | |
|
|
|
|
|
|
|
| Slight smoke or odor during initial operation | 1. | Not enough air | 1. | Check burner for dirt and debris. If | |
|
|
|
|
| found, clean burner (see Cleaning and | |
|
|
|
|
| Maintenance, page 18) | |
|
| 2. | Gas regulator defective | 2. | Replace gas control | |
|
| 3. | Residues from manufacturing processes | 3. | Problem will stop after a few hours of | |
|
|
| and logs curing |
| operation | |
|
|
|
|
|
|
|
| Moisture/condensation noticed on windows | 1. | Not enough combustion/ventilation air | 1. | Refer to Air for Combustion and Venti- | |
|
|
|
|
| lation requirements (page 4) | |
|
|
|
|
|
|
|
| Heater produces a whistling noise when | 1. | Turning control knob to HI position | 1. | Turn control knob to LO position and | |
| burner is lit |
| when burner is cold |
| let warm up for a minute | |
|
| 2. | Air in gas line | 2. | Operate burner until air is removed from | |
|
|
|
|
| line. Have gas line checked by local pro- | |
|
|
|
|
| pane/LP gas company | |
|
| 3. | Air passageways on heater blocked | 3. | Observe minimum installation clear- | |
|
|
|
|
| ances (see page 7) | |
|
| 4. | Dirty or partially clogged burner orifice | 4. | Clean burner (see Cleaning and Mainte- | |
|
|
|
|
| nance, page 18) or replace burner orifice | |
|
|
|
|
|
| |
| Dark residue on logs or inside of fireplace | 1. | Improper log placement | 1. | Properly locate logs (see Installing Gas | |
|
|
|
|
| Log Heater Into Stove, page 10 ) | |
|
| 2. | Drafts or other air currents affecting | 2. | Eliminate source of drafts around heater | |
|
|
| flame pattern |
|
|
|
|
| 3. | Air holes at burner inlet blocked | 3. | Clean out air holes at burner inlet. Peri- | |
|
|
|
|
| odically repeat as needed | |
|
| 4. | Burner flame holes blocked | 4. | Remove blockage or replace burner | |
|
|
|
|
|
|
|
White powder residue forming within burner box or on adjacent walls or furniture
1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue
1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products
Remote does not function | 1. Battery is not installed. Battery power |
| is low |
1.Replace