SPECIFICATIONS

SMA18VNA/SBJ18NVA

SMA18VPA/SBJ18VPA

• Rating (Variable): 24,000/36,000 Btu/Hr

• Rating (Variable): 24,000/36,000 Btu/Hr

• Type Gas: Natural Gas Only

Type Gas: Propane/LP Only

• Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 3.5" - 1.6" W.C.

• Manifold Pressure: 10" - 6.3" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

Max - 10.5" W.C., Min* - 5.0" W.C.

 

Max - 14" W.C., Min* - 11" W.C.

• Shipping Weight: 32 lbs.

• Shipping Weight: 32 lbs.

SMA24VNA/SBJ24VNA

SMA24VPA/SBJ24VPA

• Rating (Variable): 25,000/39,000 Btu/Hr

• Rating (Variable): 25,000/39,000 Btu/Hr

• Type Gas: Natural Gas Only

Type Gas: Propane/LP Only

• Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 3.5" - 1.6" W.C.

• Manifold Pressure: 10" - 6.3" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

Max - 10.5" W.C., Min* - 5.0" W.C.

 

Max - 14" W.C., Min* - 11" W.C.

• Shipping Weight: 34 lbs.

• Shipping Weight: 34 lbs.

* For purpose of input adjustment

 

 

Manufactured by: DESA FMI. LLC, 1769 E. Lawrence St. Russellville, AL 35653

Note: This appliance has been designed-certified by ANS Z21.11.2a-2003 Unvented Room Heaters and ANS Z21.60-2003.

Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Technical Service Department at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, con- tact your local propane/LP or natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation or troubleshooting. If so, contact DESA Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA technical services web site at www.desatech.com.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA at 1-866-672-6040 for referral information.

When calling DESA, have ready

model and serial numbers of your heater

the replacement part number

26

www.desatech.com

114744-01C

Image 26
Contents What to do if YOU Smell GAS SMA24VPATable of Contents Safety Information Provide adequate clearances around air openings Unpacking Product IdentificationLocal Codes Determining FRESH-AIR Flow for Appliance Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingAIR for Combustion Ventilation Installation Ventilation Air From OutdoorsInstallation and Clearances for VENT-FREE Operation Check GAS TypeInstallation Minimum Noncombustible Material ClearancesTo combustibles see Figure Mantel ClearancesFloor Clearances Accessory Bracket Installing Damper Clamp Accessory for Vented OperationInstalling Remote Control Masonry Manufactured FireplaceFireplaceInstallation Items Needed Installing Heater AssemblyConnecting to GAS Supply Control cover kit optional see Accessories,Natural From Checking GAS ConnectionsPropane/LP From Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Heater Gas ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Turn off heaterLighting Instructions For Your Safety Read Before LightingOperating Heater Propane/LP Natural Control Knob SwitchTo Turn OFF GAS To Appliance Shutting Off HeaterON/OFF Series Model HRC100 Manual Lighting ProcedureOptional HAND-HELD Remote Operation Thermostat Series Model HRC200Safety Features Manual ModeAuto Thermostatic Mode Auto Shutoff FeatureInspecting Burner Wiring DiagramWhen Using Remote Pilot Flame PatternPropane/LP Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyClean ODS/pilot see Out when control knob is reSafety interlock system has Low gas pressure AssemblyRemote control Tery power is low Or shut off Qualified service personBattery is not installed. Bat Gas regulator defectiveMent at top Service Hints SpecificationsReplacement Parts Technical ServiceAccessories Illustrated Parts Breakdown Parts List Models SMA24VNA Shown, SMA24VPA, SBJ24VNA and SBJ24VPA BJ24VNAS Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty