Desa SBJ24VPA, SMA18VNA, SMA24VPA Manual Lighting Procedure, Optional HAND-HELD Remote Operation

Page 18

OPERATING HEATER

Continued

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, starting on page 16.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions, page 17.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page

27). Follow instructions included with the remote control.

NOTICE: You must light the pilot

before using the hand-held re-

mote control unit. See Lighting

Instructions on page 16.

 

 

 

 

 

After lighting, let pilot flame burn for about

one minute. Turn control knob to ON posi-

tion. Adjust flame adjustment knob anywhere

between HI and LO. Flip AUTO/OFF/ON

switch to AUTO. Slide the selector switch to the

REMOTE position (see Figure 20). Note: The

burner may light if hand-held remote was on

when selector switch was last turned off. You

can now turn the burner on and off with the

hand-held remote control unit.

IMPORTANT: Do not leave the selector switch

in the REMOTE or ON position when the pilot

is not lit. This will drain the battery.

 

 

 

Selector Switch in

Control Knob

 

 

REMOTE Position

 

 

 

 

 

 

 

 

REMOTE

 

 

 

 

OFF

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF SERIES (MODEL HRC100)

Hold the control button on the hand-held remote until burner turns on. Hold the con- trol button again until burner turns off (see Figure 21).

To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed

To Unlock press both buttons together on hand- held remote control until the light stops flashing. The hand-held remote is now unlocked.

Indicator

Control

Button

Light

 

Figure 21 - On/Off Hand-Held Remote

Control Unit

THERMOSTAT SERIES (MODEL HRC200)

The hand-held remote can be operated using ei- ther the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 22, page 19). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Piezo Ignitor

Flame Adjustment Knob

Figure 20 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

18

www.desatech.com

114744-01C

Image 18
Contents What to do if YOU Smell GAS SMA24VPATable of Contents Safety Information Provide adequate clearances around air openings Product Identification Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation AIR Ventilation Air From Inside BuildingAIR for Combustion Ventilation Installation Ventilation Air From OutdoorsInstallation and Clearances for VENT-FREE Operation Check GAS TypeInstallation Minimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesTo combustibles see Figure Accessory Bracket Installing Damper Clamp Accessory for Vented OperationInstalling Remote Control Masonry Manufactured FireplaceFireplaceInstallation Items Needed Installing Heater AssemblyConnecting to GAS Supply Control cover kit optional see Accessories,Checking GAS Connections Propane/LP FromNatural From Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Pressure Testing Heater Gas ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Turn off heaterFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Propane/LP Natural Control Knob SwitchTo Turn OFF GAS To Appliance Shutting Off HeaterON/OFF Series Model HRC100 Manual Lighting ProcedureOptional HAND-HELD Remote Operation Thermostat Series Model HRC200Safety Features Manual ModeAuto Thermostatic Mode Auto Shutoff FeatureInspecting Burner Wiring DiagramWhen Using Remote Pilot Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HolePropane/LP Troubleshooting Observed Problem Possible Cause RemedyClean ODS/pilot see Out when control knob is reSafety interlock system has Low gas pressure AssemblyRemote control Tery power is low Or shut off Qualified service personBattery is not installed. Bat Gas regulator defectiveMent at top Service Hints SpecificationsReplacement Parts Technical ServiceAccessories Illustrated Parts Breakdown Parts List Models SMA24VNA Shown, SMA24VPA, SBJ24VNA and SBJ24VPA BJ24VNAS Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters