Desa SBJ18VNA, SMA18VNA, SMA24VPA, SBJ24VPA installation manual Accessories

Page 27

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

EQUIPMENT SHUTOFF

VALVE -GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

FIREPLACE HOOD

Black - GA6050, Brass - GA6052 Antique Brass - GA6053

For all models. Helps deflect heat away from mantel or wall above fireplace. Fits openings 28" to 48" wide.

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - HRC200

For all models. Allows the fireplace to be operated in a manually or thermostatically controlled mode. You can turn the fireplace on and off without ever leaving the comfort of your easy chair. A wall- mount docking station is included.

RECEIVER AND HAND-HELD REMOTE CONTROL KIT - HRC100

For all models. Allows the fireplace to be turned on and off by using a hand-held remote control. A wall-mount docking station is included.

WALL-MOUNT THERMOSTAT SWITCH - GWMT1 (Not Shown)

For all models. The desired comfort setting can be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected.

WALL-MOUNT ON/OFF SWITCH GWMS2 (Not Shown)

For all models. Allows the gas log heater to be turned on and off with a wall switch.

VENT-FREE LOGMATE® FIREBOXES (Not Shown)

Available in 32", 36" and 42" models. Circulating fireboxes feature louvers and an optional blower. Non-circulating, smooth face models are ideal for custom trim applications such as stone or marble.

FB32C (CIRCULATING), FB32NC

(NON-CIRCULATING) SERIES (Not Shown)

For all models.

FB36CA, FB42C SERIES (CIRCULATING), FB36NCA, FB42NC

SERIES (NON-CIRCULATING) (Not Shown)

For all models.

DAMPER CLAMP - GA6080 (Not Shown)

For all models. Permanently opens chimney flue damper for vented operation.

LAVA ROCK - GA6060 (Not Shown)

For all models. Order when additional rock is desired. (1.8 lb. bag)

CLEANING KIT - GCK (Not Shown)

For all models. Your vent-free gas appliance re- quires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

INFORMATION VIDEO - 108917-01

For all models. A care and maintenance video is available by calling 1-866-672-6040.

FLOOR MEDIA KIT - FM100

For all models. This kit is used to blend the edge of the burner to the fireplace floor for a more natural appearance. It includes embers, lava rock and nine fiber log pieces.

CONTROL COVER MEDIA KIT - CC100

For all models. This kit is used as an addition to or instead of the Floor Media Kit FM100. It includes 6 fiber log chunks to be placed on the fireplace floor in front of the controls for a more natural appearance.

114744-01C

www.desatech.com

27

Image 27
Contents SMA24VPA What to do if YOU Smell GASTable of Contents Safety Information Provide adequate clearances around air openings Product Identification Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors AIR for Combustion Ventilation InstallationCheck GAS Type Installation and Clearances for VENT-FREE OperationMinimum Noncombustible Material Clearances InstallationMantel Clearances Floor ClearancesTo combustibles see Figure Masonry Manufactured FireplaceFireplace Installing Damper Clamp Accessory for Vented OperationInstalling Remote Control Accessory BracketControl cover kit optional see Accessories, Installing Heater AssemblyConnecting to GAS Supply Installation Items NeededChecking GAS Connections Propane/LP FromNatural From Turn off heater Pressure Testing Heater Gas ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Shutting Off Heater Control Knob SwitchTo Turn OFF GAS To Appliance Propane/LP NaturalThermostat Series Model HRC200 Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model HRC100Auto Shutoff Feature Manual ModeAuto Thermostatic Mode Safety FeaturesPilot Flame Pattern Wiring DiagramWhen Using Remote Inspecting BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HolePropane/LP Observed Problem Possible Cause Remedy TroubleshootingLow gas pressure Assembly Out when control knob is reSafety interlock system has Clean ODS/pilot seeGas regulator defective Or shut off Qualified service personBattery is not installed. Bat Remote control Tery power is lowMent at top Technical Service SpecificationsReplacement Parts Service HintsAccessories Illustrated Parts Breakdown Parts List Models SMA24VNA Shown, SMA24VPA, SBJ24VNA and SBJ24VPA BJ24VNAS Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters