Desa SMA24VPA, SMA18VNA Check GAS Type, Installation and Clearances for VENT-FREE Operation

Page 9

INSTALLATION

Continued

WARNING: Seal any fresh air vents or ash clean-out doors located on floor or wall of fire- place. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom unless installed as a vented appliance, see page 12

in a recreational vehicle

where curtains, furniture, clothingorotherflammableob- jects are less than 42" from the front, top or sides of heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 6.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install in fireplace. Call dealer where you bought the appliance for proper type of appliance.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

INSTALLATION AND CLEARANCES FOR VENT-FREE OPERATION

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall.

MINIMUM FIREPLACE CLEARANCE TO

COMBUSTIBLE MATERIALS

SIDE WALL

 

 

16"

 

 

CEILING

 

 

42"

 

 

 

 

 

 

 

 

 

 

 

FLOOR

 

 

5"

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

 

 

MINIMUM FIREBOX SIZE

LOG

HEIGHT

DEPTH

FRONT

REAR

SIZE

 

 

 

 

 

WIDTH

WIDTH

 

 

 

 

 

 

 

18"

 

17"

 

14"

24"

20"

24"

 

17"

 

14"

28"

22"

*Measured at 14" depth.

Allow adequate clearances for accessibility for purposes of servicing and proper operation

Carefully follow the instructions below. This will ensure safe installation into masonry, UL127-listed manufactured fireplace or listed vent-free firebox.

Minimum Clearances For Side Combustible Material, Side Wall and Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 4, page 10.

Example: The face of a mantel, bookshelf, etc., is made of combustible material must be 4" from the side of the fireplace to the cabinet (see Figure 4, page 10).

B.Clearances from the top of the fireplace open- ing to the ceiling should not be less than 42".

114744-01C

www.desatech.com

9

Image 9
Contents SMA24VPA What to do if YOU Smell GASTable of Contents Safety Information Provide adequate clearances around air openings Product Identification Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors AIR for Combustion Ventilation InstallationCheck GAS Type Installation and Clearances for VENT-FREE OperationMinimum Noncombustible Material Clearances InstallationMantel Clearances Floor ClearancesTo combustibles see Figure Installing Remote Control Installing Damper Clamp Accessory for Vented OperationAccessory Bracket Masonry Manufactured FireplaceFireplaceConnecting to GAS Supply Installing Heater AssemblyInstallation Items Needed Control cover kit optional see Accessories,Checking GAS Connections Propane/LP FromNatural From Test Pressures In Excess Of 1/2 Psig 3.5 kPa Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Turn off heaterFor Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Control Knob SwitchPropane/LP Natural Shutting Off HeaterOptional HAND-HELD Remote Operation Manual Lighting ProcedureON/OFF Series Model HRC100 Thermostat Series Model HRC200Auto Thermostatic Mode Manual ModeSafety Features Auto Shutoff FeatureWhen Using Remote Wiring DiagramInspecting Burner Pilot Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HolePropane/LP Observed Problem Possible Cause Remedy TroubleshootingSafety interlock system has Out when control knob is reClean ODS/pilot see Low gas pressure AssemblyBattery is not installed. Bat Or shut off Qualified service personRemote control Tery power is low Gas regulator defectiveMent at top Replacement Parts SpecificationsService Hints Technical ServiceAccessories Illustrated Parts Breakdown Parts List Models SMA24VNA Shown, SMA24VPA, SBJ24VNA and SBJ24VPA BJ24VNAS Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters