Desa SBJ18VNA, SMA18VNA, SMA24VPA Test Pressures In Excess Of 1/2 Psig 3.5 kPa, Turn off heater

Page 15

INSTALLATION

Continued

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure ex- ternal regulator has been in- stalled between propane/LP supply and heater. See guide- lines under Connecting to Gas Supply, page 13.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater control valve regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 15).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP sup- ply to equipment shutoff valve for propane/LP

(see Figure 16 or 17). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4. Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 15).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to gas control (see Figures 16 and 17). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, page 16). Check all other internal joints for leaks.

7.Turn off heater.

Equipment Open

Shutoff

Valve

Closed

Figure 15 - Equipment Shutoff Valve

Propane/LP

Equipment Shutoff Valve

Supply

 

Tank

 

 

Control Valve

 

Location

Figure 16 - Checking Gas Joints

(Propane/LP Gas Only)

Equipment Shutoff Valve

Gas Meter

Control Valve Location

Figure 17 - Checking Gas Joints (Natural

Gas Only)

114744-01C

www.desatech.com

15

Image 15
Contents SMA24VPA What to do if YOU Smell GASTable of Contents Safety Information Provide adequate clearances around air openings Product Identification Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors AIR for Combustion Ventilation InstallationCheck GAS Type Installation and Clearances for VENT-FREE OperationMinimum Noncombustible Material Clearances InstallationMantel Clearances Floor ClearancesTo combustibles see Figure Masonry Manufactured FireplaceFireplace Installing Damper Clamp Accessory for Vented OperationInstalling Remote Control Accessory BracketControl cover kit optional see Accessories, Installing Heater AssemblyConnecting to GAS Supply Installation Items NeededChecking GAS Connections Propane/LP FromNatural From Turn off heater Pressure Testing Heater Gas ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Shutting Off Heater Control Knob SwitchTo Turn OFF GAS To Appliance Propane/LP NaturalThermostat Series Model HRC200 Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model HRC100Auto Shutoff Feature Manual ModeAuto Thermostatic Mode Safety FeaturesPilot Flame Pattern Wiring DiagramWhen Using Remote Inspecting BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HolePropane/LP Observed Problem Possible Cause Remedy TroubleshootingLow gas pressure Assembly Out when control knob is reSafety interlock system has Clean ODS/pilot seeGas regulator defective Or shut off Qualified service personBattery is not installed. Bat Remote control Tery power is lowMent at top Technical Service SpecificationsReplacement Parts Service HintsAccessories Illustrated Parts Breakdown Parts List Models SMA24VNA Shown, SMA24VPA, SBJ24VNA and SBJ24VPA BJ24VNAS Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters