Desa VGC24NR/PR, VGC30NR/PR installation manual Installing Log #1

Page 18

Installation

Continued

CAUTION: After installa- tion and periodically thereafter, check to ensure that no flame comes in contact with any log. With heater set to Hi, check to see if flames contact any log. If so, reposition logs according to log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place rear log on base assembly as shown in Figure 23. The log will fit over right end of burner and rest in the middle of U-burner.

2.Place middle log in front of U-burner and against the edges of plate as shown in Figure 24.

3.Place front left log (#3) onto pan burner be- tween log #2 and grate. Back of log #3 should fit against front of log #2. Place front right log (#4) onto pan burner between log #2 and grate. Logs #3 and #4 have notched ends to fit over end of pan burner as shown in Figure 25. Back of log #4 should fit against front of log #2.

4.Place log #5 as shown in Figure 26. Top will fit onto right pin on back log (#1). Front of log will fit onto right pin on log #2.

5.Place left crossover log (#6) over left pins on logs #1 and #2 as shown in Figure 26.

1

Figure 23 - Installing Log #1

2

Figure 24 - Installing Log #2

3

4

 

Figure 25 - Installing Logs #3 and #4

6 5

Figure 26 - Installing Logs #5 and #6

18

www.desatech.com

119162-01B

Image 18
Contents Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PR Patent PendingAlso Design-Certified As Vented Decorative Appliances Table of Contents Safety InformationSafety Information 119162-01B Local Codes Product FeaturesProduct Identification UnpackingAir For Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsFor Vent-Free Operation Installation and ClearancesCheck GAS Type Minimum Firebox SizeMaterial Requirements for Distance a Safe Installation Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor Clearances Log SetArea of Various Standard Round Flues Diameter Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Chimney Minimum PermanentConnecting to GAS Supply Installation Items NeededDealer. See Accessories, NaturalChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling optional remote accessories Pressure Testing Heater Gas ConnectionsInstalling Remote Receiver Installing Switch Installing LOGS, Embers and Lava RockInstalling Log #1 For Your Safety Read Before Lighting Operating HeaterManual Lighting Procedure, Lighting InstructionsOptional Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationOn/Off Series Model HRC100 Thermostat Series Model HRC200Key Pad Lock Feature Wiring DiagramCleaning Maintenance Inspecting BurnersBurner Injector Holder Pilot Air Inlet Hole LogsMain burner Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Slight smoke or odor during Gas leak. See Warning See Checking Gas ConnecTechnical Service SpecificationsService Hints Replacement PartsIllustrated Parts Breakdown Remote-Ready Variable Control ModelsVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Parts List Illustrated Parts Breakdown and Parts List Accessories Information video Cleaning KIT GCKLava Rock GA6060 Fire Crackle CF6-A119162-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

VGC24NR/PR, VGC30NR/PR specifications

Desa VGC24NR/PR and VGC30NR/PR are innovative gas fireplaces designed to offer efficient heating solutions while enhancing the aesthetics of any living space. Both models combine advanced technology with user-friendly features, ensuring a comfortable and visually appealing experience for homeowners.

A standout feature of the VGC series is its remarkable BTU output. The VGC24NR/PR delivers a maximum of 24,000 BTUs, while the VGC30NR/PR can generate up to 30,000 BTUs. This substantial heating capacity makes these fireplaces suitable for various room sizes, providing warmth even in larger spaces. The adjustable heat settings also allow users to customize the warmth according to their preferences, promoting energy efficiency.

Another significant characteristic of the VGC24NR/PR and VGC30NR/PR is their realistic flame presentation. Utilizing advanced burner technology, these units replicate the look of natural wood burning fires. The flames dance against the backdrop of elegant logs or stones, creating a cozy atmosphere that enhances any interior décor. The visual experience is elevated by the optional ember bed lighting, which can provide an ambient glow, making the fireplace a focal point in the room.

Safety is a paramount consideration in the design of these fireplaces. Both models are equipped with built-in safety features, including an automatic shut-off system that activates in the event of a malfunction. Additionally, they meet stringent safety and emissions standards, ensuring that they are environmentally friendly choices.

Installation is straightforward with the VGC series, thanks to their ventless design that allows for flexibility in placement. These units can be installed in a variety of locations without the need for an external venting system, making them an ideal solution for both new constructions and remodels. The minimalist design also aids in space-saving, making it easy to integrate into compact living areas.

Furthermore, the Desa VGC24NR/PR and VGC30NR/PR come with user-friendly controls, including options for remote operation and wall switches, which add convenience to daily use. With their combination of efficiency, aesthetic appeal, and safety features, these gas fireplaces represent an excellent choice for anyone looking to enhance their home’s comfort and charm.