Desa VGC24NR/PR, VGC30NR/PR installation manual Lighting Instructions, Manual Lighting Procedure

Page 20

Operating Heater

Continued

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE:Duringinitialoperationof new heater, burning logs will give offapaper-burningsmell.Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to op- erate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information on page 19.

2.Make sure equipment shutoff valve is fully open.

3.Set switch to OFF position.

4.Press in and turn control knob clockwise to the OFF position (see Figure 29).

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 19. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counter-

clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 29).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button on left side of log set. This will light pilot. The pilot is attached to the front of U-shaped burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see

Manual Lighting Procedure, page 21.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

• If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8, page 20 and above.

9.Slightly push in and turn control knob coun-

terclockwise to the ON position. If using a hand-held remote control accessory, go to Optional Hand-Held Remote Operation on page 21.

 

Flame

Control

 

Knob in OFF

 

Adjustment

Ignitor

Position

Knob

 

 

AUTO

OFF

ON

Selector Switch

Figure 29 - Control Knob, Ignitor Button

and AUTO/OFF/ON Switch

20

www.desatech.com

119162-01B

Image 20
Contents Also Design-Certified As Vented Decorative Appliances Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PRPatent Pending Table of Contents Safety InformationSafety Information 119162-01B Product Features Product IdentificationLocal Codes UnpackingDetermining FRESH-AIR Flow for Heater Location Air For Combustion VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsInstallation and Clearances Check GAS TypeFor Vent-Free Operation Minimum Firebox SizeMantel Clearances Material Requirements for Distance a Safe InstallationDetermining Minimum Mantel Clearance When Using a Hood Floor Clearances Log SetInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyArea of Various Standard Round Flues Diameter Chimney Minimum PermanentConnecting to GAS Supply Installation Items NeededDealer. See Accessories, NaturalChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Remote Receiver Installing optional remote accessoriesPressure Testing Heater Gas Connections Installing Switch Installing LOGS, Embers and Lava RockInstalling Log #1 For Your Safety Read Before Lighting Operating HeaterManual Lighting Procedure, Lighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationOn/Off Series Model HRC100 Thermostat Series Model HRC200Wiring Diagram Cleaning MaintenanceKey Pad Lock Feature Inspecting BurnersMain burner Burner Injector Holder Pilot Air Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Slight smoke or odor during Gas leak. See Warning See Checking Gas ConnecSpecifications Service HintsTechnical Service Replacement PartsVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Illustrated Parts BreakdownRemote-Ready Variable Control Models Parts List Illustrated Parts Breakdown and Parts List Accessories Cleaning KIT GCK Lava Rock GA6060Information video Fire Crackle CF6-A119162-01B Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

VGC24NR/PR, VGC30NR/PR specifications

Desa VGC24NR/PR and VGC30NR/PR are innovative gas fireplaces designed to offer efficient heating solutions while enhancing the aesthetics of any living space. Both models combine advanced technology with user-friendly features, ensuring a comfortable and visually appealing experience for homeowners.

A standout feature of the VGC series is its remarkable BTU output. The VGC24NR/PR delivers a maximum of 24,000 BTUs, while the VGC30NR/PR can generate up to 30,000 BTUs. This substantial heating capacity makes these fireplaces suitable for various room sizes, providing warmth even in larger spaces. The adjustable heat settings also allow users to customize the warmth according to their preferences, promoting energy efficiency.

Another significant characteristic of the VGC24NR/PR and VGC30NR/PR is their realistic flame presentation. Utilizing advanced burner technology, these units replicate the look of natural wood burning fires. The flames dance against the backdrop of elegant logs or stones, creating a cozy atmosphere that enhances any interior décor. The visual experience is elevated by the optional ember bed lighting, which can provide an ambient glow, making the fireplace a focal point in the room.

Safety is a paramount consideration in the design of these fireplaces. Both models are equipped with built-in safety features, including an automatic shut-off system that activates in the event of a malfunction. Additionally, they meet stringent safety and emissions standards, ensuring that they are environmentally friendly choices.

Installation is straightforward with the VGC series, thanks to their ventless design that allows for flexibility in placement. These units can be installed in a variety of locations without the need for an external venting system, making them an ideal solution for both new constructions and remodels. The minimalist design also aids in space-saving, making it easy to integrate into compact living areas.

Furthermore, the Desa VGC24NR/PR and VGC30NR/PR come with user-friendly controls, including options for remote operation and wall switches, which add convenience to daily use. With their combination of efficiency, aesthetic appeal, and safety features, these gas fireplaces represent an excellent choice for anyone looking to enhance their home’s comfort and charm.