Desa VGC30NR/PR To Turn OFF GAS To Appliance, Manual Lighting Procedure, Optional Hand-Held

Page 21

Operating Heater

Continued

10.Wait one minute and put switch in ON posi- tion to light burners. Note: AUTO is only functional when using GWMT1 or GWMS2 optional accessories. If hand-held remote control is installed but not being used, slide remote selector switch to ON (It must be in this position for burners to light. Switch will be in REMOTE position if using hand-held remote).

11.Set flame adjustment knob to any level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

WARNING: Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on auto- matically with selector switch in the ON position.

Pilot

Ignitor

Burner

Electrode

 

Figure 30 - Pilot (Propane/LP)

Pilot Burner

Ignitor

 

Electrode

Figure 31 - Pilot (Natural)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise to the OFF position.

2a. Set switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery.

Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise to the PILOT position.

2.Use remote control manual OFF button.

3.Set switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 20.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, Lighting Instructions, page 20.

Optional Hand-Held

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 33). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 20.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Ad- just flame adjustment knob anywhere between HI and LO. Slide the selector switch to the RE- MOTE position (see Figure 32, page 22). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

119162-01B

www.desatech.com

21

Image 21
Contents Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PR Patent PendingAlso Design-Certified As Vented Decorative Appliances Safety Information Table of ContentsSafety Information 119162-01B Product Identification Product FeaturesLocal Codes UnpackingAir For Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installation and ClearancesFor Vent-Free Operation Minimum Firebox SizeMaterial Requirements for Distance a Safe Installation Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Log Set Floor ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationArea of Various Standard Round Flues Diameter Chimney Minimum PermanentInstallation Items Needed Connecting to GAS SupplyNatural Dealer. See Accessories,Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsInstalling optional remote accessories Pressure Testing Heater Gas ConnectionsInstalling Remote Receiver Installing LOGS, Embers and Lava Rock Installing SwitchInstalling Log #1 Operating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure,To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 On/Off Series Model HRC100Cleaning Maintenance Wiring DiagramKey Pad Lock Feature Inspecting BurnersBurner Injector Holder Pilot Air Inlet Hole LogsMain burner Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Slight smoke or odor during See Checking Gas Connec Gas leak. See WarningService Hints SpecificationsTechnical Service Replacement PartsIllustrated Parts Breakdown Remote-Ready Variable Control ModelsVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Parts List Illustrated Parts Breakdown and Parts List Accessories Lava Rock GA6060 Cleaning KIT GCKInformation video Fire Crackle CF6-A119162-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

VGC24NR/PR, VGC30NR/PR specifications

Desa VGC24NR/PR and VGC30NR/PR are innovative gas fireplaces designed to offer efficient heating solutions while enhancing the aesthetics of any living space. Both models combine advanced technology with user-friendly features, ensuring a comfortable and visually appealing experience for homeowners.

A standout feature of the VGC series is its remarkable BTU output. The VGC24NR/PR delivers a maximum of 24,000 BTUs, while the VGC30NR/PR can generate up to 30,000 BTUs. This substantial heating capacity makes these fireplaces suitable for various room sizes, providing warmth even in larger spaces. The adjustable heat settings also allow users to customize the warmth according to their preferences, promoting energy efficiency.

Another significant characteristic of the VGC24NR/PR and VGC30NR/PR is their realistic flame presentation. Utilizing advanced burner technology, these units replicate the look of natural wood burning fires. The flames dance against the backdrop of elegant logs or stones, creating a cozy atmosphere that enhances any interior décor. The visual experience is elevated by the optional ember bed lighting, which can provide an ambient glow, making the fireplace a focal point in the room.

Safety is a paramount consideration in the design of these fireplaces. Both models are equipped with built-in safety features, including an automatic shut-off system that activates in the event of a malfunction. Additionally, they meet stringent safety and emissions standards, ensuring that they are environmentally friendly choices.

Installation is straightforward with the VGC series, thanks to their ventless design that allows for flexibility in placement. These units can be installed in a variety of locations without the need for an external venting system, making them an ideal solution for both new constructions and remodels. The minimalist design also aids in space-saving, making it easy to integrate into compact living areas.

Furthermore, the Desa VGC24NR/PR and VGC30NR/PR come with user-friendly controls, including options for remote operation and wall switches, which add convenience to daily use. With their combination of efficiency, aesthetic appeal, and safety features, these gas fireplaces represent an excellent choice for anyone looking to enhance their home’s comfort and charm.