Desa VGC30NR/PR, VGC24NR/PR Operating Heater, For Your Safety Read Before Lighting

Page 19

Installation

Continued

6.Add embers to front flat burner. Gently remove embers from the bag using gloves or tweezers.

(This material is a skin irritant. Gloves or tweezers are recommended to prevent skin irritation). Separate pieces of ember material and place over surface of flat burner (see Figure 27). Spread ember material evenly over surface for greatest glowing effect. Do

NOT place ember material anywhere else on the unit. Use only ember material sup- plied with unit. Excessive ember material may produce carbon monoxide or soot.

WARNING: Do not use rock wool or any other ember material not supplied with this unit.

WARNING: Do not operate unit without ember material correctly in place as shown in Figure 27.

7.Place center crossover log (#7) onto pin on log #5 and resting on grate as shown in Figure 28. Log #7 must overlap grate and rest against grate finger. Log must not rest on burner.

8.Add lava rock and small decorative logs around base of heater if desired. DO NOT place rock or additional logs on front burner or on logs. Placing any material on unit other than ember material on front burner may result in production of carbon monoxide or soot. Use lava rock to hide wires from switch/log to control valve. Place switch/log so the switch is easy to access.

Ember

Material Flat Front

Burner

Figure 27 - Placement of Embers

7

Figure 28 - Installing Log #7

Operating Heater

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

119162-01B

www.desatech.com

19

Image 19
Contents Patent Pending Remote-Ready Models VGC18NR/PR VGC24NR/PR and VGC30NR/PRAlso Design-Certified As Vented Decorative Appliances Safety Information Table of ContentsSafety Information 119162-01B Unpacking Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation Air For Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationMinimum Firebox Size Installation and ClearancesCheck GAS Type For Vent-Free OperationDetermining Minimum Mantel Clearance When Using a Hood Material Requirements for Distance a Safe InstallationMantel Clearances Log Set Floor ClearancesChimney Minimum Permanent Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round Flues DiameterInstallation Items Needed Connecting to GAS SupplyNatural Dealer. See Accessories,Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsPressure Testing Heater Gas Connections Installing optional remote accessoriesInstalling Remote Receiver Installing LOGS, Embers and Lava Rock Installing SwitchInstalling Log #1 Operating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure,Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldThermostat Series Model HRC200 On/Off Series Model HRC100Inspecting Burners Wiring DiagramCleaning Maintenance Key Pad Lock FeatureLogs Burner Injector Holder Pilot Air Inlet HoleMain burner Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Slight smoke or odor during See Checking Gas Connec Gas leak. See WarningReplacement Parts SpecificationsService Hints Technical ServiceRemote-Ready Variable Control Models Illustrated Parts BreakdownVGC18NR, VGC18PR, VGC24NR, VGC24PR, VGC30NR, VGC30PR Parts List Illustrated Parts Breakdown and Parts List Accessories Fire Crackle CF6-A Cleaning KIT GCKLava Rock GA6060 Information video119162-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

VGC24NR/PR, VGC30NR/PR specifications

Desa VGC24NR/PR and VGC30NR/PR are innovative gas fireplaces designed to offer efficient heating solutions while enhancing the aesthetics of any living space. Both models combine advanced technology with user-friendly features, ensuring a comfortable and visually appealing experience for homeowners.

A standout feature of the VGC series is its remarkable BTU output. The VGC24NR/PR delivers a maximum of 24,000 BTUs, while the VGC30NR/PR can generate up to 30,000 BTUs. This substantial heating capacity makes these fireplaces suitable for various room sizes, providing warmth even in larger spaces. The adjustable heat settings also allow users to customize the warmth according to their preferences, promoting energy efficiency.

Another significant characteristic of the VGC24NR/PR and VGC30NR/PR is their realistic flame presentation. Utilizing advanced burner technology, these units replicate the look of natural wood burning fires. The flames dance against the backdrop of elegant logs or stones, creating a cozy atmosphere that enhances any interior décor. The visual experience is elevated by the optional ember bed lighting, which can provide an ambient glow, making the fireplace a focal point in the room.

Safety is a paramount consideration in the design of these fireplaces. Both models are equipped with built-in safety features, including an automatic shut-off system that activates in the event of a malfunction. Additionally, they meet stringent safety and emissions standards, ensuring that they are environmentally friendly choices.

Installation is straightforward with the VGC series, thanks to their ventless design that allows for flexibility in placement. These units can be installed in a variety of locations without the need for an external venting system, making them an ideal solution for both new constructions and remodels. The minimalist design also aids in space-saving, making it easy to integrate into compact living areas.

Furthermore, the Desa VGC24NR/PR and VGC30NR/PR come with user-friendly controls, including options for remote operation and wall switches, which add convenience to daily use. With their combination of efficiency, aesthetic appeal, and safety features, these gas fireplaces represent an excellent choice for anyone looking to enhance their home’s comfort and charm.