Installing Logs (Cont.)

OPERATING HEATER

For Your Safety Read Before Lighting

15

INSTALLATION

Continued

3.Align peg on right support bracket with hole in bottom of right side log (#3). Place log over peg and over last grate finger on right as shown in Figure 25.

4.Place left end of front log (#4) under left side log (#2). Align hole in bottom of right end of log #4 with peg in front of right support bracket (see Figure 26). Lower log onto peg.

5.Align holes in bottom of crossover log #5 with pegs on top of rear log (#1) and front log (#4) (see Figure 27). It may be nec- essary to adjust log #4 to align holes with pegs. Place cross- over log onto pegs (see Figure 28).

6.The effect of glowing embers can be created by placing rock wool on front burner. For best effect, use only the smallest amount necessary to create the glow. Tear rock wool into dime- size pieces and place pieces on and around front burner. Do

NOT place rock wool in area of pilot or rear burner.

7.Add lava rock around base to heater if desired. Do not place lava rock on logs or burner. Do NOT place lava rock on or around front burner.

CAUTION: Placing lava rock on or around front burner will cause severe sooting. Please keep ember material (rock wool) separate from lava rock.

Log #1

Log #2

Left Support

Bracket

Figure 25 - Installing Left

Figure 24 - Installing Rear Log (#2)

Log (#1)

Log #4

Log #3

Log #2

 

Right

Support

Bracket

Grate

Finger

 

Peg

Figure 26 - Installing Right

Figure 27 - Installing Front

Log (#3)

Log (#4)

Log #5

Peg on Log #1

 

Peg on Log #4

Place Rock Wool On

Front Burner For Glowing

Ember Effect

Figure 28 - Installing Crossover Log (#5)

OPERATING HEATER

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

For morevisit www..com

111640-01B

Image 15
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsVent-Free Gas Log Heater Product IdentificationUnpacking Product FeaturesRemote Control Accessories Local CodesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Minimum Firebox Size Log Front Rear Height Depth Width InstallationCheck GAS Type Log Size Side Wall CeilingMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Floor ClearancesMinimum Chimney Permanent Flue Height ft. Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemInstalling Optional Remote Accessories Pressure Testing Heater Gas ConnectionsInstalling Remote Receiver Installing 9-Volt Battery in Receiver Installing LogsOperating Heater For Your Safety Read Before LightingShutting Off Burners Only pilot stays lit Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterON/OFF Series Model Cghrcb Manual Lighting ProcedureManual Mode Optional HAND-HELD Remote OperationPilot Flame Pattern Auto Thermostatic ModeSafety Features Inspecting BurnersCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Gas leak. See Warning statement at TopTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsModels VGL24PR and VGL24NR Illustrated Parts BreakdownKEY Part Number VGL24PR VGL24NR Description QTY Parts ListFireplace Hood Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Cghrcb Series Equipment Shutoff ValveOwners Registration Form Postage Required 111640-01B Warranty Information

VGL24PR, VGL24NR specifications

Desa VGL24NR and VGL24PR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. With their modern design and advanced technologies, these gas fireplaces offer both aesthetic appeal and functional performance.

One of the main features of the VGL24NR and VGL24PR models is their ventless operation. This means they do not require a chimney or venting system, making them an ideal choice for various installation scenarios. The lack of venting not only simplifies the installation process but also allows for more flexible placement within a room, enabling users to enjoy the warmth and ambiance of a fire wherever it fits best.

These models are equipped with a versatile heating capacity that can efficiently warmth up spaces of various sizes. With an impressive output, they are perfect for both cozy living rooms and larger family areas. The adjustable flame height allows users to customize their heat output, optimizing energy use while still achieving desired warmth levels.

In terms of technology, the Desa VGL24NR and VGL24PR feature advanced safety systems that ensure peace of mind for users. The oxygen depletion sensor automatically shuts off the unit if oxygen levels fall below a safe threshold. This invaluable feature makes these fireplaces a safe choice, particularly in enclosed environments.

Both models are designed with user convenience in mind. The easy-to-use remote control provides effortless operation, allowing users to adjust the flame and heat settings from the comfort of their seats. The wide viewing area enhances the visual appeal, providing a stunning flame display that can serve as a focal point in any room.

With regard to aesthetics, the Desa VGL24NR and VGL24PR come in a variety of finishes and styles, catering to diverse design preferences. Whether one prefers a contemporary look or a more traditional aesthetic, these fireplaces can seamlessly complement any décor.

Energy efficiency is another hallmark of the VGL24NR and VGL24PR models. They utilize clean-burning gas, which not only minimizes environmental impact but also reduces heating costs. By heating spaces quickly and effectively, these fireplaces provide an economical heating solution with long-term benefits.

In summary, the Desa VGL24NR and VGL24PR gas fireplaces combine modern design with innovative technology and robust safety features. Their ventless operation, adjustable heat output, and remote functionality make them suitable for various applications, enhancing comfort and style in any setting. For those seeking a reliable and aesthetically pleasing heating solution, these models offer an excellent option.