Desa VGL24NR Cleaning Maintenance, Cleaning Burner Injector Holder and Pilot AIR Inlet Hole, Logs

Page 19

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole

Logs

Main Burner

19

CLEANING AND

MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. In- spect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to exces- sive lint from carpeting, bedding material, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in soot- ing and property damage.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes in rear burner for dust and dirt (see Figure 36).

3.Blow air through the holes in the burner.

4.Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 37). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Primary Air

Inlet Holes

Injector

 

Holder

Burner Tube

Figure 36 - Injector Holder On Outlet Burner Tube

Pilot Air

Holes in Burner

Inlet Hole

Pilot

Assembly

 

Figure 37 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 14 and 15, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage, blocked burner flame holes will create soot.

For morevisit www..com

111640-01B

Image 19
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsVent-Free Gas Log Heater Product IdentificationUnpacking Product FeaturesRemote Control Accessories Local CodesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Minimum Firebox Size Log Front Rear Height Depth Width InstallationCheck GAS Type Log Size Side Wall CeilingMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Floor ClearancesMinimum Chimney Permanent Flue Height ft. Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemPressure Testing Heater Gas Connections Installing Optional Remote AccessoriesInstalling Remote Receiver Installing 9-Volt Battery in Receiver Installing LogsOperating Heater For Your Safety Read Before LightingShutting Off Burners Only pilot stays lit Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterON/OFF Series Model Cghrcb Manual Lighting ProcedureManual Mode Optional HAND-HELD Remote OperationPilot Flame Pattern Auto Thermostatic ModeSafety Features Inspecting BurnersCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Gas leak. See Warning statement at TopTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsModels VGL24PR and VGL24NR Illustrated Parts BreakdownKEY Part Number VGL24PR VGL24NR Description QTY Parts ListFireplace Hood Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Cghrcb Series Equipment Shutoff ValveOwners Registration Form Postage Required 111640-01B Warranty Information

VGL24PR, VGL24NR specifications

Desa VGL24NR and VGL24PR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. With their modern design and advanced technologies, these gas fireplaces offer both aesthetic appeal and functional performance.

One of the main features of the VGL24NR and VGL24PR models is their ventless operation. This means they do not require a chimney or venting system, making them an ideal choice for various installation scenarios. The lack of venting not only simplifies the installation process but also allows for more flexible placement within a room, enabling users to enjoy the warmth and ambiance of a fire wherever it fits best.

These models are equipped with a versatile heating capacity that can efficiently warmth up spaces of various sizes. With an impressive output, they are perfect for both cozy living rooms and larger family areas. The adjustable flame height allows users to customize their heat output, optimizing energy use while still achieving desired warmth levels.

In terms of technology, the Desa VGL24NR and VGL24PR feature advanced safety systems that ensure peace of mind for users. The oxygen depletion sensor automatically shuts off the unit if oxygen levels fall below a safe threshold. This invaluable feature makes these fireplaces a safe choice, particularly in enclosed environments.

Both models are designed with user convenience in mind. The easy-to-use remote control provides effortless operation, allowing users to adjust the flame and heat settings from the comfort of their seats. The wide viewing area enhances the visual appeal, providing a stunning flame display that can serve as a focal point in any room.

With regard to aesthetics, the Desa VGL24NR and VGL24PR come in a variety of finishes and styles, catering to diverse design preferences. Whether one prefers a contemporary look or a more traditional aesthetic, these fireplaces can seamlessly complement any décor.

Energy efficiency is another hallmark of the VGL24NR and VGL24PR models. They utilize clean-burning gas, which not only minimizes environmental impact but also reduces heating costs. By heating spaces quickly and effectively, these fireplaces provide an economical heating solution with long-term benefits.

In summary, the Desa VGL24NR and VGL24PR gas fireplaces combine modern design with innovative technology and robust safety features. Their ventless operation, adjustable heat output, and remote functionality make them suitable for various applications, enhancing comfort and style in any setting. For those seeking a reliable and aesthetically pleasing heating solution, these models offer an excellent option.