Desa VGL24NR Wiring Diagram Replacement Parts, Specifications, Service Hints, Technical Service

Page 23

WIRING DIAGRAM SPECIFICATIONS SERVICE HINTS TECHNICAL SERVICE REPLACEMENT PARTS

23

WIRING DIAGRAM

REPLACEMENT PARTS

On

Off Receiver

Remote

Thermopile

Black

Red

TPTH TH

Gas Control

TPTH TP

Red

White

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

your name

your address

SPECIFICATIONS

 

VGL24PR

VGL24NR

Btu (Variable)

21,000/30,000

21,000/30,000

Type Gas

Propane/LP Only

Natural Gas Only

Ignition

Electronic

Electronic

Manifold Pressure

8.0" W.C.

3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14"

10.5"

Minimum*

11"

5"

* For the purpose of input adjustment

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical service web site at www.desatech.com.

• model and serial numbers of your heater

• how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen- tral (see page 26) or call DESA Heating Products at 1-866-672-6040 for referral information.

When calling DESA Heating Products, have ready

model number of your heater

the replacement part number

For morevisit www..com

111640-01B

Image 23
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsVent-Free Gas Log Heater Product IdentificationUnpacking Product FeaturesRemote Control Accessories Local CodesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Minimum Firebox Size Log Front Rear Height Depth Width InstallationCheck GAS Type Log Size Side Wall CeilingMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Floor ClearancesMinimum Chimney Permanent Flue Height ft. Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemInstalling Remote Receiver Installing Optional Remote AccessoriesPressure Testing Heater Gas Connections Installing 9-Volt Battery in Receiver Installing LogsOperating Heater For Your Safety Read Before LightingShutting Off Burners Only pilot stays lit Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterON/OFF Series Model Cghrcb Manual Lighting ProcedureManual Mode Optional HAND-HELD Remote OperationPilot Flame Pattern Auto Thermostatic ModeSafety Features Inspecting BurnersLogs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Gas leak. See Warning statement at TopTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsModels VGL24PR and VGL24NR Illustrated Parts BreakdownKEY Part Number VGL24PR VGL24NR Description QTY Parts ListFireplace Hood Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Cghrcb Series Equipment Shutoff ValveOwners Registration Form Postage Required 111640-01B Warranty Information

VGL24PR, VGL24NR specifications

Desa VGL24NR and VGL24PR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. With their modern design and advanced technologies, these gas fireplaces offer both aesthetic appeal and functional performance.

One of the main features of the VGL24NR and VGL24PR models is their ventless operation. This means they do not require a chimney or venting system, making them an ideal choice for various installation scenarios. The lack of venting not only simplifies the installation process but also allows for more flexible placement within a room, enabling users to enjoy the warmth and ambiance of a fire wherever it fits best.

These models are equipped with a versatile heating capacity that can efficiently warmth up spaces of various sizes. With an impressive output, they are perfect for both cozy living rooms and larger family areas. The adjustable flame height allows users to customize their heat output, optimizing energy use while still achieving desired warmth levels.

In terms of technology, the Desa VGL24NR and VGL24PR feature advanced safety systems that ensure peace of mind for users. The oxygen depletion sensor automatically shuts off the unit if oxygen levels fall below a safe threshold. This invaluable feature makes these fireplaces a safe choice, particularly in enclosed environments.

Both models are designed with user convenience in mind. The easy-to-use remote control provides effortless operation, allowing users to adjust the flame and heat settings from the comfort of their seats. The wide viewing area enhances the visual appeal, providing a stunning flame display that can serve as a focal point in any room.

With regard to aesthetics, the Desa VGL24NR and VGL24PR come in a variety of finishes and styles, catering to diverse design preferences. Whether one prefers a contemporary look or a more traditional aesthetic, these fireplaces can seamlessly complement any décor.

Energy efficiency is another hallmark of the VGL24NR and VGL24PR models. They utilize clean-burning gas, which not only minimizes environmental impact but also reduces heating costs. By heating spaces quickly and effectively, these fireplaces provide an economical heating solution with long-term benefits.

In summary, the Desa VGL24NR and VGL24PR gas fireplaces combine modern design with innovative technology and robust safety features. Their ventless operation, adjustable heat output, and remote functionality make them suitable for various applications, enhancing comfort and style in any setting. For those seeking a reliable and aesthetically pleasing heating solution, these models offer an excellent option.