Desa VGL24PR, VGL24NR installation manual Installing Logs, Installing 9-Volt Battery in Receiver

Page 14

14

INSTALLATION

Installing Optional Remote Accessories (Cont.) Installing Logs

INSTALLATION

Continued

8.

Install remote receiver into receiver bracket using pads and

 

push button clips provided with receiver (see Figure 20).

9.

Connect wires to control valve at the TPTH and TH locations

 

as shown in Figure 21. Note: Make sure excess wire does not

 

interfere with burner or pilot.

10.

If heater was removed from fireplace before installation of re-

 

mote accessory, see Installing Heater Base Assembly on pages

 

10 and 11 to reinstall heater into fireplace. Test gas connection

Installing 9-Volt Battery (Not Included) in Hand- Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery. Place battery into the bat- tery housing.

3.Replace battery cover onto remote control unit.

for leaks (see Checking Gas Connections, pages 11 and 12).

11. If logs were removed from heater for install remote accessory,

replace logs (see Installing Logs, pages 14 and 15).

Terminal Wires

Battery Cover

9-Volt

Battery

Battery

9-Volt Battery

Battery Housing

Remote Control Unit

 

 

Clip

 

 

Terminal

 

 

Wires

Push Button

Bracket

Pad

Clips

 

 

Figure 20 - Installing Remote Receiver

 

White

 

 

Wire From

 

 

Receiver

 

Control

 

 

Valve

 

Red Wire From

 

 

Receiver

 

Figure 21 - Connecting Wires

 

Installing Batteries for Remote Receiver and Hand Held Remote Control

Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1.Locate back of receiver behind receiver bracket mounted on base assembly.

2.Locate the battery clip mounted on the back of the receiver (see Figure 20).

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Figure 22 - Installing Battery in Hand-Held Remote Control Unit (CGHRCB Series)

9-Volt

Terminal

Remote

Wires

Battery

 

Control Unit

 

 

Battery Cover

Battery

 

 

Housing

 

 

Figure 23 - Installing Battery in Hand-Held Remote Control Unit (CGHRCTB Series)

INSTALLING LOGS

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to HI, check to see if flames contact any log. If so, reposition logs accord- ing to the log installation instructions in this manual. Flames contacting logs will create soot.

1.Align two pegs near rear of base behind support brackets with two holes in bottom of rear log (#1). Place logs on pegs (see Figure 24, page 15).

2.Align two pegs in left support bracket with holes in bottom of left side log (#2). Place log on pegs (see Figure 25, page 15).

Forvisit..com

111640-01B

Image 14
Contents Unvented VENT-FREE GAS LOG Heater What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Vent-Free Gas Log HeaterLocal Codes Product FeaturesRemote Control Accessories UnpackingConfined Space and Unconfined Space Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Log Size Side Wall Ceiling InstallationCheck GAS Type Minimum Firebox Size Log Front Rear Height Depth WidthIf Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Determining Minimum Mantel ClearancesInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Minimum Chimney Permanent Flue Height ft. Opening sq. insConnecting to GAS Supply Attaching Base Assembly to Fireplace FloorPressure Testing Gas Supply Piping system Checking GAS ConnectionsInstalling Remote Receiver Installing Optional Remote AccessoriesPressure Testing Heater Gas Connections Installing Logs Installing 9-Volt Battery in ReceiverFor Your Safety Read Before Lighting Operating HeaterShutting Off Heater Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off Burners Only pilot stays litOptional HAND-HELD Remote Operation Manual Lighting ProcedureManual Mode ON/OFF Series Model CghrcbInspecting Burners Auto Thermostatic ModeSafety Features Pilot Flame PatternLogs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedySee Wiring Diagram, Top Gas leak. See Warning statement atService Hints Wiring Diagram Replacement PartsSpecifications Technical ServiceIllustrated Parts Breakdown Models VGL24PR and VGL24NRParts List KEY Part Number VGL24PR VGL24NR Description QTYEquipment Shutoff Valve Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Cghrcb Series Fireplace HoodOwners Registration Form Postage Required 111640-01B Warranty Information

VGL24PR, VGL24NR specifications

Desa VGL24NR and VGL24PR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. With their modern design and advanced technologies, these gas fireplaces offer both aesthetic appeal and functional performance.

One of the main features of the VGL24NR and VGL24PR models is their ventless operation. This means they do not require a chimney or venting system, making them an ideal choice for various installation scenarios. The lack of venting not only simplifies the installation process but also allows for more flexible placement within a room, enabling users to enjoy the warmth and ambiance of a fire wherever it fits best.

These models are equipped with a versatile heating capacity that can efficiently warmth up spaces of various sizes. With an impressive output, they are perfect for both cozy living rooms and larger family areas. The adjustable flame height allows users to customize their heat output, optimizing energy use while still achieving desired warmth levels.

In terms of technology, the Desa VGL24NR and VGL24PR feature advanced safety systems that ensure peace of mind for users. The oxygen depletion sensor automatically shuts off the unit if oxygen levels fall below a safe threshold. This invaluable feature makes these fireplaces a safe choice, particularly in enclosed environments.

Both models are designed with user convenience in mind. The easy-to-use remote control provides effortless operation, allowing users to adjust the flame and heat settings from the comfort of their seats. The wide viewing area enhances the visual appeal, providing a stunning flame display that can serve as a focal point in any room.

With regard to aesthetics, the Desa VGL24NR and VGL24PR come in a variety of finishes and styles, catering to diverse design preferences. Whether one prefers a contemporary look or a more traditional aesthetic, these fireplaces can seamlessly complement any décor.

Energy efficiency is another hallmark of the VGL24NR and VGL24PR models. They utilize clean-burning gas, which not only minimizes environmental impact but also reduces heating costs. By heating spaces quickly and effectively, these fireplaces provide an economical heating solution with long-term benefits.

In summary, the Desa VGL24NR and VGL24PR gas fireplaces combine modern design with innovative technology and robust safety features. Their ventless operation, adjustable heat output, and remote functionality make them suitable for various applications, enhancing comfort and style in any setting. For those seeking a reliable and aesthetically pleasing heating solution, these models offer an excellent option.