INSTALLATION

Installing Heater Base Assembly (Cont.) Connecting To Gas Supply

11

INSTALLATION

Continued

4.Place logs in their proper positions on heater base.

5.Center heater base and logs front-to-back and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

7.Mark screw locations through holes in mounting flanges (see Figure 12). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

8.Remove heater base from fireplace.

9.Drill holes at marked locations using 3/16" masonry drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12).

11.Connect to gas supply. See Connecting To Gas Supply.

Masonry

Screw

Mounting

Flanges

Figure 12 - Attaching Base Assembly to Fireplace Floor

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pres- sure regulator.

WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 26.

For propane/LP units, the installer must supply an external regula- tor. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent point- ing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diam- eter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14, page 12).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

CAUTION: Never connect propane/LP heater di- rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

WARNING: Never connect natural gas heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Propane/LP

Supply Tank

External

Regulator

Vent Pointing

Down

Figure 13 - External Regulator With Vent Pointing Down

For morevisit www..com

111640-01B

Image 11
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsVent-Free Gas Log Heater Product IdentificationUnpacking Product FeaturesRemote Control Accessories Local CodesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined Space and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Minimum Firebox Size Log Front Rear Height Depth Width InstallationCheck GAS Type Log Size Side Wall CeilingMinimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Floor ClearancesMinimum Chimney Permanent Flue Height ft. Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemInstalling Remote Receiver Installing Optional Remote AccessoriesPressure Testing Heater Gas Connections Installing 9-Volt Battery in Receiver Installing LogsOperating Heater For Your Safety Read Before LightingShutting Off Burners Only pilot stays lit Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterON/OFF Series Model Cghrcb Manual Lighting ProcedureManual Mode Optional HAND-HELD Remote OperationPilot Flame Pattern Auto Thermostatic ModeSafety Features Inspecting BurnersLogs Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Gas leak. See Warning statement at TopTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsModels VGL24PR and VGL24NR Illustrated Parts BreakdownKEY Part Number VGL24PR VGL24NR Description QTY Parts ListFireplace Hood Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Cghrcb Series Equipment Shutoff ValveOwners Registration Form Postage Required 111640-01B Warranty Information

VGL24PR, VGL24NR specifications

Desa VGL24NR and VGL24PR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. With their modern design and advanced technologies, these gas fireplaces offer both aesthetic appeal and functional performance.

One of the main features of the VGL24NR and VGL24PR models is their ventless operation. This means they do not require a chimney or venting system, making them an ideal choice for various installation scenarios. The lack of venting not only simplifies the installation process but also allows for more flexible placement within a room, enabling users to enjoy the warmth and ambiance of a fire wherever it fits best.

These models are equipped with a versatile heating capacity that can efficiently warmth up spaces of various sizes. With an impressive output, they are perfect for both cozy living rooms and larger family areas. The adjustable flame height allows users to customize their heat output, optimizing energy use while still achieving desired warmth levels.

In terms of technology, the Desa VGL24NR and VGL24PR feature advanced safety systems that ensure peace of mind for users. The oxygen depletion sensor automatically shuts off the unit if oxygen levels fall below a safe threshold. This invaluable feature makes these fireplaces a safe choice, particularly in enclosed environments.

Both models are designed with user convenience in mind. The easy-to-use remote control provides effortless operation, allowing users to adjust the flame and heat settings from the comfort of their seats. The wide viewing area enhances the visual appeal, providing a stunning flame display that can serve as a focal point in any room.

With regard to aesthetics, the Desa VGL24NR and VGL24PR come in a variety of finishes and styles, catering to diverse design preferences. Whether one prefers a contemporary look or a more traditional aesthetic, these fireplaces can seamlessly complement any décor.

Energy efficiency is another hallmark of the VGL24NR and VGL24PR models. They utilize clean-burning gas, which not only minimizes environmental impact but also reduces heating costs. By heating spaces quickly and effectively, these fireplaces provide an economical heating solution with long-term benefits.

In summary, the Desa VGL24NR and VGL24PR gas fireplaces combine modern design with innovative technology and robust safety features. Their ventless operation, adjustable heat output, and remote functionality make them suitable for various applications, enhancing comfort and style in any setting. For those seeking a reliable and aesthetically pleasing heating solution, these models offer an excellent option.