Desa VGL24NR Installing Optional Remote Accessories, Pressure Testing Heater Gas Connections

Page 13

INSTALLATION

Checking Gas Connections (Cont.) Installing Optional Remote Accessories

13

INSTALLATION

Continued

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 15, page 12).

2.Open propane/LP supply tank valve or main gas valve located on or near gas meter for natural gas.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from propane/LP supply tank to equipment shutoff valve for propane/LP gas (see Figure 16) or from gas meter to equipment shutoff valve for natural gas (see Figure 17). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 15 through 18). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 16).

Equipment

Shutoff Valve

Propane/LP

Tank

Valve Location

INSTALLING OPTIONAL REMOTE

ACCESSORIES

Installing Remote Receiver

Remote control accessories are available separately (see Accesso- ries, page 26).

1.If unit is already installed in fireplace, continue with these in- structions. If unit has not been installed in fireplace, go to step 6 and continue installation of remote accessory.

WARNING: Turn off heater and let cool before handling any part of heater. Make sure gas is turned of to unit.

2.Carefully remove logs and set aside.

3.Locate mounting screws on sides of heater base assembly and remove screws. Set screws aside for reinstallation.

4.Disconnect gas line from heater base as shown in Figure 11, page 10.

WARNING: A qualified service person must con- nect and disconnect gas to heater. Follow all local codes.

5.Remove heater base from fireplace.

6.Install receiver bracket to base with phillips screws provided in hardware kit as shown in Figure 18.

7.Disconnect jumper wire from control valve at TPTH and TH locations (see Figure 19).

Figure 16 - Checking Gas Joints

Equipment Shutoff Valve

Gas Meter

Remote

Receiver

Bracket

Phillips

Screws

Figure 17 - Checking Gas Joints

Figure 18 - Installing Remote Receiver Bracket

Jumper

Wire

Control

Valve

Figure 19 - Disconnecting Jumper Wire from Control Valve

For morevisit www..com

111640-01B

Image 13
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsVent-Free Gas Log Heater Product IdentificationRemote Control Accessories Product FeaturesLocal Codes UnpackingUnusually Tight Construction Determining FRESH-AIR Flow for Heater LocationConfined Space and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationLog Size Side Wall Ceiling Minimum Firebox Size Log Front Rear Height Depth WidthMinimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Determining Minimum Mantel Clearances When Using a HoodFloor Clearances Determining Minimum Mantel ClearancesInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Minimum Chimney Permanent Flue Height ft. Opening sq. insAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemPressure Testing Heater Gas Connections Installing Optional Remote AccessoriesInstalling Remote Receiver Installing 9-Volt Battery in Receiver Installing LogsOperating Heater For Your Safety Read Before LightingTo Turn OFF GAS To Appliance Lighting InstructionsShutting Off Heater Shutting Off Burners Only pilot stays litManual Mode Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model CghrcbSafety Features Auto Thermostatic ModeInspecting Burners Pilot Flame PatternCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Gas leak. See Warning statement at TopSpecifications Wiring Diagram Replacement PartsService Hints Technical ServiceModels VGL24PR and VGL24NR Illustrated Parts BreakdownKEY Part Number VGL24PR VGL24NR Description QTY Parts ListReceiver and HAND-HELD Remote Control KIT Cghrcb Series Cleaning KIT CCKEquipment Shutoff Valve Fireplace HoodOwners Registration Form Postage Required 111640-01B Warranty Information

VGL24PR, VGL24NR specifications

Desa VGL24NR and VGL24PR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. With their modern design and advanced technologies, these gas fireplaces offer both aesthetic appeal and functional performance.

One of the main features of the VGL24NR and VGL24PR models is their ventless operation. This means they do not require a chimney or venting system, making them an ideal choice for various installation scenarios. The lack of venting not only simplifies the installation process but also allows for more flexible placement within a room, enabling users to enjoy the warmth and ambiance of a fire wherever it fits best.

These models are equipped with a versatile heating capacity that can efficiently warmth up spaces of various sizes. With an impressive output, they are perfect for both cozy living rooms and larger family areas. The adjustable flame height allows users to customize their heat output, optimizing energy use while still achieving desired warmth levels.

In terms of technology, the Desa VGL24NR and VGL24PR feature advanced safety systems that ensure peace of mind for users. The oxygen depletion sensor automatically shuts off the unit if oxygen levels fall below a safe threshold. This invaluable feature makes these fireplaces a safe choice, particularly in enclosed environments.

Both models are designed with user convenience in mind. The easy-to-use remote control provides effortless operation, allowing users to adjust the flame and heat settings from the comfort of their seats. The wide viewing area enhances the visual appeal, providing a stunning flame display that can serve as a focal point in any room.

With regard to aesthetics, the Desa VGL24NR and VGL24PR come in a variety of finishes and styles, catering to diverse design preferences. Whether one prefers a contemporary look or a more traditional aesthetic, these fireplaces can seamlessly complement any décor.

Energy efficiency is another hallmark of the VGL24NR and VGL24PR models. They utilize clean-burning gas, which not only minimizes environmental impact but also reduces heating costs. By heating spaces quickly and effectively, these fireplaces provide an economical heating solution with long-term benefits.

In summary, the Desa VGL24NR and VGL24PR gas fireplaces combine modern design with innovative technology and robust safety features. Their ventless operation, adjustable heat output, and remote functionality make them suitable for various applications, enhancing comfort and style in any setting. For those seeking a reliable and aesthetically pleasing heating solution, these models offer an excellent option.