Desa VN2550ITA, VN1800ITA Technical Service, Service Publications Hints, VN1800D VN3000D

Page 30

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE PUBLICATIONS

SERVICE

HINTS

30

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

VN1800ITA

VN2550ITA

Btu (Variable)

6,600-18,000

7,000-25,500

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

6" W.C.

6" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

10.5"

Minimum

7"

7"

Dimensions, Inches (H x W x D)

 

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

 

 

Heater

24

32

Shipping

29

38

 

 

 

 

VN1800D

VN3000D

Btu (Variable)

6,600/12,000/18,000

6,600/18,000/30,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

6" W.C.

6" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

10.5"

Minimum

7"

7"

Dimensions, Inches (H x W x D)

 

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

 

 

Heater

22

30

Shipping

27

36

Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

When gas pressure is too low

pilot will not stay lit

burner(s) will have delayed ignition

heater will not produce specified heat

When gas quality is bad

pilot will not stay lit

burner(s) will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

101822

Image 30
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Combustion and Ventilation, pages 5 through Local Codes Unpacking Product Features ProductIdentification Ventilation Fresh AIR ForCombustion Producing Adequate VentilationFresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsCheck GAS Type Installing To WallInstallation Items Locating HeaterLocating Thermostat Sensing Bulb Thermostat Sensing BulbModels VN1800ITA and VN2550ITA Only Attaching Thermostat Sensing BulbRemoving Front Panel Of Heater Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Connections Pressure Testing GAS Supply Piping SystemChecking GAS Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections Checking GAS ConnectionsOperating Heater Operating Heater Lighting InstructionsHeater To Select Heating LevelShutting Off Heater Shutting Off Burner Only pilot stays litIf you do not follow these instructions exactly, a fire or Explosion may result causing property damage, personalOperating Injury or loss of lifeModels VN1800D and VN3000D LOW MED High Inspecting Burner Pilot Flame PatternBurner Flame Pattern If burner flame pattern is incorrect, as shown in FigureCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice Air PassagewaysObserved Possible Remedy Problem Cause TROUBLE- ShootingTrouble Shooting See CleaningDo not try to light any appliance If you smell gasShut off gas supply Ing statement atTechnical Service Service Publications HintsVN1800D VN3000D Replacement Parts AccessoriesIllustrated Parts Breakdown Model VN1800ITAParts List Model VN2550ITA Parts List Model VN1800D Control Position Label Hardware Assembly Model VN3000D Parts List Warranty Information Keep this Warranty