Desa VN3000D, VN1800ITA, VN1800D TROUBLE- Shooting, Observed Possible Remedy Problem Cause

Page 27

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

REMEDY

PROBLEM

CAUSE

 

 

 

 

 

When ignitor button is

1.

Gas supply turned off or

1.

Turn on gas supply or

pressed in, there is a

 

manual shutoff valve

 

open manual shutoff

spark at ODS/pilot but

 

closed.

 

valve.

no ignition.

2.

Control knob not fully

2.

Fully press in control

 

 

pressed in while pressing

 

knob while pressing igni-

 

 

ignitor button (non-

 

tor button (non-thermo-

 

 

thermostat models only).

 

stat models only).

 

 

Thermostat control knob

 

Fully press in thermostat

 

 

not fully pressed in while

 

control knob while press-

 

 

pressing ignitor button

 

ing ignitor button (ther-

 

 

(thermostat models only).

 

mostat models only).

 

3.

Air in gas lines when

3.

Continue holding down

 

 

installed.

 

control knob. Repeat

 

 

 

 

igniting operation until

 

 

 

 

air is removed.

 

4.

ODS/pilot is clogged.

4.

Clean ODS/pilot (see

 

 

 

 

Cleaning and Mainte-

 

 

 

 

nance, page 26) or

 

 

 

 

replace ODS/pilot

 

 

 

 

assembly.

 

5.

Gas regulator setting is

5.

Replace gas regulator.

 

 

not correct.

 

 

 

6.

Thermostat control knob

6.

Turn thermostat control

 

 

not in pilot position.

 

knob to pilot position.

ODS/pilot lights but

1.

Control knob not fully

flame goes out when

 

pressed in.

control knob is

2.

Control knob not pressed

released

 

in long enough.

 

3.

Manual shutoff valve not

 

 

fully open.

 

4.

Thermocouple connection

 

 

loose at control valve.

 

5.

Pilot flame not touching

 

 

thermocouple, which

 

 

allows thermocouple to

 

 

cool, causing pilot flame

 

 

to go out. This problem

 

 

could be caused by one or

 

 

both of the following:

 

 

A) Low gas pressure

 

 

B) Dirty or partially

 

 

clogged ODS/pilot

 

6.

Thermocouple damaged.

 

7.

Control valve damaged.

 

8.

Safety interlock system

 

 

has been triggered

 

 

(thermostat models only).

1.Press in control knob fully.

2.After ODS/pilot lights, keep control knob pressed in 30 seconds.

3.Fully open manual shut- off valve.

4.Hand tighten until snug, then tighten 1/4 turn more.

5.A) Contact local natural gas company.

B)Clean ODS/pilot (see Cleaning and Mainte- nance, page 26) or replace ODS/pilot assembly.

6.Replace thermocouple.

7.Replace control valve.

8.Wait one minute for safety interlock system to reset. Repeat ignition operation.

Continued

101822

27

Image 27
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Combustion and Ventilation, pages 5 through Local Codes Unpacking Product Features ProductIdentification Producing Adequate Ventilation Fresh AIR ForCombustion VentilationFresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsLocating Heater Installing To WallInstallation Items Check GAS TypeAttaching Thermostat Sensing Bulb Thermostat Sensing BulbModels VN1800ITA and VN2550ITA Only Locating Thermostat Sensing BulbMethods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Servicing. Correct all leaks at once Pressure Testing GAS Supply Piping SystemChecking GAS ConnectionsChecking GAS Connections Pressure Testing Heater GAS ConnectionsOperating Heater Lighting Instructions Operating HeaterTo Select Heating Level HeaterShutting Off Burner Only pilot stays lit Shutting Off HeaterInjury or loss of life Explosion may result causing property damage, personalOperating If you do not follow these instructions exactly, a fire orModels VN1800D and VN3000D LOW MED High Pilot Flame Pattern Inspecting BurnerIf burner flame pattern is incorrect, as shown in Figure Burner Flame PatternAir Passageways Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice CabinetTROUBLE- Shooting Observed Possible Remedy Problem CauseSee Cleaning Trouble ShootingIng statement at If you smell gasShut off gas supply Do not try to light any applianceTechnical Service Service Publications HintsVN1800D VN3000D Accessories Replacement PartsModel VN1800ITA Illustrated Parts BreakdownParts List Model VN2550ITA Parts List Model VN1800D Control Position Label Hardware Assembly Model VN3000D Parts List Keep this Warranty Warranty Information