Page 11
C-clockwise
C-clockwise

OPERATING HEATER (Manual Control Blue Flame Models)

For Your Safety Read Before Lighting

Lighting Instructions

11

OPERATING HEATER

MANUAL CONTROL BLUE FLAME

MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step.

5.Press in control knob and turn counterclockwise C-clockwiseto the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 17).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release igni- tor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 17 through 19. Also contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 12.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8. Turn control knob counterclockwise to the HIGH position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from HIGH to a lower setting, press in the control

knob and turn counterclockwise .

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor Button Control Knob

PILOT OFF

HIGH

IGNITOR

LOW

Figure 17 - Control Knob In The OFF Position

 

Ignitor Electrode

Thermocouple

Pilot Burner

 

Figure 18 - Pilot

For more information, visit www.desatech.com

107902-01D

Image 11
Contents What to do if YOU Smell GAS GWN6, GWP6GWN10T, GWP10T GWRN10 and GWRP10 Safety Information Table of ContentsLocal Codes Product FeaturesUnpacking Product IdentificationDetermining FRESH-AIR Flow for Heater Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Heater InstallationInstallation Items Check GAS TypePlacing Heater On Mounting Screws Installing Heater to WallInstalling Two Mounting Screws Marking Screw LocationsRemoving Front Panel Of Heater Connecting to GAS SupplyInstalling Bottom Mounting Screw Checking GAS Connections Pressure Testing Gas Supply Piping SystemReplace front panel Pressure Testing Heater Gas ConnectionsLighting Instructions Operating HeaterShutting Off Burner Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterBurner Patterns To Select Heating LevelThermostat Control Operation Burner Flame Pattern Infrared Models Inspecting BurnerPilot Flame Pattern Burner Flame Pattern Blue Flame ModelsCabinet Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole ODS/PILOT and Burner OrificeObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at GWP6 GWN6 GWP10 GWN10 Pilot Illustrated Parts BreakdownKEY Part Number for GWP6 GWN6 GWP10 GWN10 Description QTY Parts ListGWRP10 GWRN10 KEY Part Number GWRP10 GWRN10 Description QTY GWP10T GWN10T Pilot KEY Part Number GWP10T GWN10T Description QTY GWP6 GWP10 GWRP10 GWP10T SpecificationsService Publications Accessory Replacement PartsService Hints Technical ServiceBaltimore Electric Parts CentralsOwners Registration Form Postage Required 107902-01D Warranty Information

GWN10T, GWP10T, GWRN10, GWN6, GWP6 specifications

Desa GWN10, GWP10, GWRP10, GWP6, and GWN6 are innovative products designed to meet diverse demands in various sectors. Each model brings unique features and characteristics, tailored for specific applications in the world of technology and daily use.

Desa GWN10 is recognized for its robust design and energy efficiency. It employs advanced wireless communication technology, enabling seamless integration with smart home systems. The GWN10 stands out with its high performance in terms of connectivity range and reliability. It offers users the convenience of remote monitoring and control, making it ideal for residential and commercial use, especially in areas that require a secure and efficient energy solution.

GWP10, on the other hand, is engineered for flexibility and versatility. Its modular design allows users to configure the system according to their specific needs. The GWP10 utilizes cutting-edge battery technology, providing longer usage times and faster charging capabilities. With its user-friendly interface and cloud connectivity, users can easily track energy consumption and optimize settings for enhanced performance.

The GWRP10 is a game-changer in renewable energy applications. Equipped with advanced solar integration technologies, it can harness solar power effectively, making it an eco-friendly choice. The GWRP10 features intelligent energy management systems that optimize power distribution, ensuring that energy is used efficiently. This model is perfect for users looking to reduce their carbon footprint while enjoying reliable power supply.

GWP6, a compact powerhouse, offers exceptional performance in a smaller footprint. Its lightweight construction and easy installation make it suitable for urban environments where space is a premium. The GWP6 leverages latest communication standards, such as IoT connectivity, providing real-time data insights for users. This makes it ideal for mobile applications and temporary installations.

Finally, the GWN6 emphasizes portability and ease of use. With its rugged design, it is perfect for outdoor activities and off-grid solutions. The GWN6 includes battery backup options, ensuring uninterrupted power during outdoor adventures. Its durable build and waterproof features make it reliable for challenging environments.

Together, these models showcase Desa’s commitment to innovation, sustainability, and user-centric design. Whether for energy management, renewable energy integration, or portable power, Desa GWN10, GWP10, GWRP10, GWP6, and GWN6 provide advanced solutions for contemporary needs. Their groundbreaking technologies and features are setting new standards in their respective categories, making them valuable assets for both everyday consumers and businesses alike.