Desa GWP10, GWRN10 Inspecting Burner, Pilot Flame Pattern, Burner Flame Pattern Blue Flame Models

Page 15

INSPECTING BURNER

Pilot Flame Pattern

Burner Flame Pattern Blue Flame Models

Burner Flame Pattern Infrared Models

15

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 25

turn heater off (see To Turn Off Gas to Appliance, pages 12, 13 or 14 depending on your model)

see Troubleshooting, pages 17 through 19

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

 

Pilot

Pilot Burner

Burner

Thermocouple

Thermocouple

 

Figure 24 - Correct Pilot Flame

Figure 25 - Incorrect Pilot Flame

Pattern

Pattern

BURNER FLAME PATTERN

BLUE FLAME MODELS

Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

WARNING: If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, proceed with the following instructions.

NOTICE: Do not mistake orange flames with yellow tipping. Dust or other fine particles enter the heater and burn causing brief patches of orange flame.

If burner flame pattern is incorrect, as shown in Figure 27

turn heater off (see To Turn Off Gas to Appliance, pages 12 or 14 depending on your model)

see Troubleshooting, pages 17 through 19

1/2 GLASS HEIGHT

(Models GWN6 and GWP6 will be lower due to lower input rating)

Figure 26 - Correct Burner Flame Pattern

Yellow

Tipping

1/2 GLASS HEIGHT

Figure 27 - Incorrect Burner Flame Pattern

BURNER FLAME PATTERN

INFRARED MODELS

Figure 28 shows a correct burner flame pattern. Figure 29 shows an incorrect burner flame pattern.

If burner flame pattern is incorrect, as shown in Figure 29

turn heater off (see To Turn Off Gas to Appliance, page 13 or 14)

see Troubleshooting, pages 17 through 19

Figure 28 - Correct Burner

Figure 29 - Incorrect Burner

Flame Pattern

Flame Pattern

For more information, visit www.desatech.com

107902-01D

Image 15
Contents GWN6, GWP6 GWN10T, GWP10T GWRN10 and GWRP10What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product FeaturesUnpacking Product IdentificationAIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypePlacing Heater On Mounting Screws Installing Heater to WallInstalling Two Mounting Screws Marking Screw LocationsConnecting to GAS Supply Installing Bottom Mounting ScrewRemoving Front Panel Of Heater Checking GAS Connections Pressure Testing Gas Supply Piping SystemReplace front panel Pressure Testing Heater Gas ConnectionsLighting Instructions Operating Heater Shutting Off Burner Only pilot stays lit Manual Lighting Procedure To Turn OFF GAS To Appliance Shutting Off HeaterBurner Patterns To Select Heating LevelThermostat Control Operation Burner Flame Pattern Infrared Models Inspecting BurnerPilot Flame Pattern Burner Flame Pattern Blue Flame ModelsCabinet Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole ODS/PILOT and Burner OrificeObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at GWP6 GWN6 GWP10 GWN10 Pilot Illustrated Parts BreakdownKEY Part Number for GWP6 GWN6 GWP10 GWN10 Description QTY Parts ListGWRP10 GWRN10 KEY Part Number GWRP10 GWRN10 Description QTY GWP10T GWN10T Pilot KEY Part Number GWP10T GWN10T Description QTY GWP6 GWP10 GWRP10 GWP10T SpecificationsService Publications Accessory Replacement PartsService Hints Technical ServiceBaltimore Electric Parts CentralsOwners Registration Form Postage Required 107902-01D Warranty Information