TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice is clogged

1.

Clean burner orifice (see Cleaning and

 

 

 

 

Maintenance, page 16) or replace burner

 

 

 

 

orifice

 

2.

Inlet gas pressure is too low

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

 

 

 

 

Delayed ignition of burner

1.

Manifold pressure is too low

1.

Contact local natural or propane/LP gas

 

 

 

 

company

 

2.

Burner orifice is clogged

2.

Clean burner orifice (see Cleaning and

 

 

 

 

Maintenance, page 16) or replace burner

 

 

 

 

orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner orifice (see Cleaning and

 

 

 

 

Maintenance, page 16) or replace burner

 

 

 

 

orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Burner plaque(s) does not glow (Infrared

1.

Control knob set between locked positions

1.

Turn control knob until it locks at de-

models only)

 

 

 

sired setting

 

2.

Inlet gas pressure is too low

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

Plaque damaged

3.

Replace burner

 

 

 

 

 

Yellow flame during burner combustion

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

Maintenance, page 16)

 

2.

Inlet gas pressure is too low

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

 

 

 

 

operation

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HIGH position

1.

Turn control knob to LOW position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas checked by local natural

 

 

 

 

or propane/LP gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see Figure 4, page 7)

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 16) or replace burner orifice

 

 

 

 

 

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

For morevisit www..com

107902-01D

Image 18
Contents GWN6, GWP6 GWN10T, GWP10T GWRN10 and GWRP10What to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification Product FeaturesUnpacking Local CodesAIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating HeaterMarking Screw Locations Installing Heater to WallInstalling Two Mounting Screws Placing Heater On Mounting ScrewsConnecting to GAS Supply Installing Bottom Mounting ScrewRemoving Front Panel Of Heater Pressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Replace front panelOperating Heater Lighting InstructionsShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burner Only pilot stays litTo Select Heating Level Burner PatternsThermostat Control Operation Burner Flame Pattern Blue Flame Models Inspecting Burner Pilot Flame Pattern Burner Flame Pattern Infrared ModelsODS/PILOT and Burner Orifice Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Illustrated Parts Breakdown GWP6 GWN6 GWP10 GWN10 PilotParts List KEY Part Number for GWP6 GWN6 GWP10 GWN10 Description QTYGWRP10 GWRN10 KEY Part Number GWRP10 GWRN10 Description QTY GWP10T GWN10T Pilot KEY Part Number GWP10T GWN10T Description QTY Specifications GWP6 GWP10 GWRP10 GWP10TTechnical Service Replacement PartsService Hints Service Publications AccessoryParts Centrals Baltimore ElectricOwners Registration Form Postage Required 107902-01D Warranty Information