Desa GWRP10, GWRN10, GWN6, GWP10T, GWP6, GWN10T Table of Contents, Safety Information

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

UNPACKING

3

PRODUCT IDENTIFICATION

3

PRODUCT FEATURES

3

LOCAL CODES

3

AIR FOR COMBUSTION AND VENTILATION

4

INSTALLATION

6

OPERATING HEATER

11

INSPECTING BURNER

15

CLEANING AND MAINTENANCE

16

TROUBLESHOOTING

17

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

20

SPECIFICATIONS

26

REPLACEMENT PARTS

27

SERVICE HINTS

27

TECHNICAL SERVICE

27

SERVICE PUBLICATIONS

27

ACCESSORY

27

PARTS CENTRALS

28

OWNER’S REGISTRATION FORM

29

WARRANTY INFORMATION

Back Cover

SAFETY INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or ser- vice this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are fuel gases. Fuel gases are odorless. An odor-making agent is added to fuel gases. The odor helps you detect a fuel gas leak. However, the odor added to fuel gas can fade. Fuel gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use any accessory not ap- proved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot sur- face to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

Carefully supervise young children when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.Do not install 10,000 Btu units in a bathroom.

For morevisit www..com

107902-01D

Image 2
Contents What to do if YOU Smell GAS GWN6, GWP6GWN10T, GWP10T GWRN10 and GWRP10 Table of Contents Safety InformationProduct Identification Product FeaturesUnpacking Local CodesDetermining FRESH-AIR Flow for Heater Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating HeaterMarking Screw Locations Installing Heater to WallInstalling Two Mounting Screws Placing Heater On Mounting ScrewsRemoving Front Panel Of Heater Connecting to GAS SupplyInstalling Bottom Mounting Screw Pressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Replace front panelOperating Heater Lighting InstructionsShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burner Only pilot stays litTo Select Heating Level Burner PatternsThermostat Control Operation Burner Flame Pattern Blue Flame Models Inspecting BurnerPilot Flame Pattern Burner Flame Pattern Infrared ModelsODS/PILOT and Burner Orifice Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Illustrated Parts Breakdown GWP6 GWN6 GWP10 GWN10 PilotParts List KEY Part Number for GWP6 GWN6 GWP10 GWN10 Description QTYGWRP10 GWRN10 KEY Part Number GWRP10 GWRN10 Description QTY GWP10T GWN10T Pilot KEY Part Number GWP10T GWN10T Description QTY Specifications GWP6 GWP10 GWRP10 GWP10TTechnical Service Replacement PartsService Hints Service Publications AccessoryParts Centrals Baltimore ElectricOwners Registration Form Postage Required 107902-01D Warranty Information

GWN10T, GWP10T, GWRN10, GWN6, GWP6 specifications

Desa GWN10, GWP10, GWRP10, GWP6, and GWN6 are innovative products designed to meet diverse demands in various sectors. Each model brings unique features and characteristics, tailored for specific applications in the world of technology and daily use.

Desa GWN10 is recognized for its robust design and energy efficiency. It employs advanced wireless communication technology, enabling seamless integration with smart home systems. The GWN10 stands out with its high performance in terms of connectivity range and reliability. It offers users the convenience of remote monitoring and control, making it ideal for residential and commercial use, especially in areas that require a secure and efficient energy solution.

GWP10, on the other hand, is engineered for flexibility and versatility. Its modular design allows users to configure the system according to their specific needs. The GWP10 utilizes cutting-edge battery technology, providing longer usage times and faster charging capabilities. With its user-friendly interface and cloud connectivity, users can easily track energy consumption and optimize settings for enhanced performance.

The GWRP10 is a game-changer in renewable energy applications. Equipped with advanced solar integration technologies, it can harness solar power effectively, making it an eco-friendly choice. The GWRP10 features intelligent energy management systems that optimize power distribution, ensuring that energy is used efficiently. This model is perfect for users looking to reduce their carbon footprint while enjoying reliable power supply.

GWP6, a compact powerhouse, offers exceptional performance in a smaller footprint. Its lightweight construction and easy installation make it suitable for urban environments where space is a premium. The GWP6 leverages latest communication standards, such as IoT connectivity, providing real-time data insights for users. This makes it ideal for mobile applications and temporary installations.

Finally, the GWN6 emphasizes portability and ease of use. With its rugged design, it is perfect for outdoor activities and off-grid solutions. The GWN6 includes battery backup options, ensuring uninterrupted power during outdoor adventures. Its durable build and waterproof features make it reliable for challenging environments.

Together, these models showcase Desa’s commitment to innovation, sustainability, and user-centric design. Whether for energy management, renewable energy integration, or portable power, Desa GWN10, GWP10, GWRP10, GWP6, and GWN6 provide advanced solutions for contemporary needs. Their groundbreaking technologies and features are setting new standards in their respective categories, making them valuable assets for both everyday consumers and businesses alike.