OPERATING HEATER (Manual Control Blue Flame Models)

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

OPERATING HEATER (Manual Control Infrared Models)

For Your Safety Read Before Lighting

11

OPERATING HEATER

Continued

6.With control knob pressed in, push down and release igni- tor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 16 through 18. Also contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8. Turn control knob counterclockwise to the HIGH position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from HIGH to a lower setting, press in the control

knob and turn counterclockwise .

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Turn control knob clockwise

Clockwise

to the PILOT position.

2.

Press in control knob and turn clockwise Clockwise to the

 

OFF position.

 

 

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 7).

2.Follow steps 1 through 5 under Lighting Instructions, page 10.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after pilot is lit. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions.

5.Replace front panel.

Ignitor Button

Control Knob

PILOT

OFF

HIGH

 

IGNITOR

 

LOW

 

Figure 17 - Control Knob In The OFF Position

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 18 - Pilot

MANUAL CONTROL INFRARED MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

For more information, visit www.desatech.com

110720-01A

Image 11
Contents What to do if YOU Smell GAS VENT-FREE GAS HeaterSafety Information Table of ContentsLocal Codes Product FeaturesUnpacking Product IdentificationConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building AIR for CombustionVentilation Ventilation AIRLocating Heater InstallationInstallation Items Check GAS TypePlacing Heater On Mounting Screws Installing Heater to WallInstalling Two Mounting Screws Marking Screw LocationsInstalling Bottom Mounting Screw Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemLighting Instructions Pressure Testing Heater Gas ConnectionsOperating Heater Shutting Off Burner Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterBurner Patterns To Select Heating LevelOFF Position Shown Burner Flame Pattern Blue Flame Models Inspecting BurnerThermostat Control Operation Pilot Flame PatternODS/PILOT and Burner Orifice Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole Burner Flame Pattern Infrared ModelsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at VP600BA VP5D VP10A VP1000BTA SpecificationsVN600BA VP600BA Pilot Illustrated Parts BreakdownKEY Part Number for VP600BA VN600BA Description QTY Parts ListVP10A VN10A KEY Part Number VP10A VN10A Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot KEY Part Number VP1000BTA VN1000BTA Description QTY Accessory Replacement PartsTechnical Service Service PublicationsOwners Registration Form Postage Required Baltimore Electric Parts CentralsWarranty Information

VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, VP5D, VP1000BTA VN10A, VP10A specifications

The Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models represent a remarkable lineup in the realm of ventilation and heating solutions. Each of these models is designed with specific features and technologies that cater to diverse needs, enhancing comfort and efficiency in residential and commercial environments.

Starting with the VP600BA and VN600BA, these models provide robust heating capabilities paired with user-friendly interfaces. Highlighting energy efficiency, both units are engineered to minimize energy consumption while maximizing output. The VN1000BTA and VP1000BTA step up the game with advanced thermostatic controls. These models not only provide reliable heating but also enable precise temperature regulation, ensuring optimal comfort levels.

The VN10A and VP10A models are tailored for versatility, accommodating various space sizes without compromising performance. Equipped with high-efficiency burners, they deliver consistent warmth even in colder climates. The VN6D and VP5D models are compact yet powerful, making them perfect for smaller spaces or areas where installation flexibility is essential. Their lightweight design allows for easy maneuverability while maintaining high-temperature output.

Innovative technologies define these models, with features like electronic ignition systems that provide a hassle-free start-up experience. Many bear smart technology integration, allowing users to control settings remotely via smartphone applications. This level of interactivity signifies a growing trend in home automation, where convenience is key.

The aesthetics of these models cannot be overlooked. With sleek designs and customizable options, they seamlessly blend into a variety of interior decors, enhancing the overall ambiance of any space. The builds are also designed for durability, featuring corrosion-resistant materials that assure longevity.

In terms of safety, these models incorporate multiple redundancies, including automatic shut-off features and robust flame management systems. Hence, user peace of mind is guaranteed alongside effective heating solutions.

Overall, the Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models exemplify a harmonious balance of function, technology, and design, making them ideal choices for heating and ventilation in contemporary settings. Their array of features ensures each unit meets the specific demands of users, providing an energy-efficient and comfortable environment regardless of the application.