Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, VP5D Table of Contents

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

UNPACKING

3

PRODUCT IDENTIFICATION

3

PRODUCT FEATURES

3

LOCAL CODES

3

AIR FOR COMBUSTION AND VENTILATION

4

INSTALLATION

6

OPERATING HEATER

10

INSPECTING BURNER

14

CLEANING AND MAINTENANCE

15

TROUBLESHOOTING

16

SPECIFICATIONS

19

ILLUSTRATED PARTS BREAKDOWN

20

ILLUSTRATED PARTS BREAKDOWN

24

REPLACEMENT PARTS

28

SERVICE HINTS

28

TECHNICAL SERVICE

28

SERVICE PUBLICATIONS

28

ACCESSORY

28

OWNER’S REGISTRATION FORM

29

PARTS CENTRALS

31

WARRANTY INFORMATION

Back Cover

SAFETY INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or ser- vice this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are fuel gases. Fuel gases are odorless. An odor-making agent is added to fuel gases. The odor helps you detect a fuel gas leak. However, the odor added to fuel gas can fade. Fuel gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use any accessory not ap- proved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot sur- face to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

Carefully supervise young children when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.Do not install 10,000 Btu units in a bathroom.

For morevisit www..com

110720-01A

Image 2
Contents VENT-FREE GAS Heater What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product FeaturesUnpacking Local CodesDetermining FRESH-AIR Flow for Heater Location AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceVentilation AIR AIR for CombustionVentilation Ventilation Air From Inside BuildingCheck GAS Type InstallationInstallation Items Locating HeaterMarking Screw Locations Installing Heater to WallInstalling Two Mounting Screws Placing Heater On Mounting ScrewsConnecting to GAS Supply Installing Bottom Mounting ScrewPressure Testing Gas Supply Piping System Checking GAS ConnectionsLighting Instructions Pressure Testing Heater Gas ConnectionsOperating Heater Shutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burner Only pilot stays litTo Select Heating Level Burner PatternsOFF Position Shown Pilot Flame Pattern Inspecting BurnerThermostat Control Operation Burner Flame Pattern Blue Flame ModelsBurner Flame Pattern Infrared Models Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole ODS/PILOT and Burner OrificeTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Specifications VP600BA VP5D VP10A VP1000BTAIllustrated Parts Breakdown VN600BA VP600BA PilotParts List KEY Part Number for VP600BA VN600BA Description QTYVP10A VN10A KEY Part Number VP10A VN10A Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot KEY Part Number VP1000BTA VN1000BTA Description QTY Service Publications Replacement PartsTechnical Service AccessoryOwners Registration Form Postage Required Parts Centrals Baltimore ElectricWarranty Information

VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, VP5D, VP1000BTA VN10A, VP10A specifications

The Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models represent a remarkable lineup in the realm of ventilation and heating solutions. Each of these models is designed with specific features and technologies that cater to diverse needs, enhancing comfort and efficiency in residential and commercial environments.

Starting with the VP600BA and VN600BA, these models provide robust heating capabilities paired with user-friendly interfaces. Highlighting energy efficiency, both units are engineered to minimize energy consumption while maximizing output. The VN1000BTA and VP1000BTA step up the game with advanced thermostatic controls. These models not only provide reliable heating but also enable precise temperature regulation, ensuring optimal comfort levels.

The VN10A and VP10A models are tailored for versatility, accommodating various space sizes without compromising performance. Equipped with high-efficiency burners, they deliver consistent warmth even in colder climates. The VN6D and VP5D models are compact yet powerful, making them perfect for smaller spaces or areas where installation flexibility is essential. Their lightweight design allows for easy maneuverability while maintaining high-temperature output.

Innovative technologies define these models, with features like electronic ignition systems that provide a hassle-free start-up experience. Many bear smart technology integration, allowing users to control settings remotely via smartphone applications. This level of interactivity signifies a growing trend in home automation, where convenience is key.

The aesthetics of these models cannot be overlooked. With sleek designs and customizable options, they seamlessly blend into a variety of interior decors, enhancing the overall ambiance of any space. The builds are also designed for durability, featuring corrosion-resistant materials that assure longevity.

In terms of safety, these models incorporate multiple redundancies, including automatic shut-off features and robust flame management systems. Hence, user peace of mind is guaranteed alongside effective heating solutions.

Overall, the Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models exemplify a harmonious balance of function, technology, and design, making them ideal choices for heating and ventilation in contemporary settings. Their array of features ensures each unit meets the specific demands of users, providing an energy-efficient and comfortable environment regardless of the application.