Desa VP1000BTA VN10A, VP10A installation manual KEY Part Number VP5D VN6D Description QTY

Page 25

PARTS LIST

VP5D, VN6D

25

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.

KEY

PART NUMBER

 

 

NO.

VP5D

VN6D

DESCRIPTION

QTY.

1

098304-01

098304-01

Screw, #10 x 3/8"

2

2

099467-03

099467-03

Front Panel Assembly

1

3

099318-03

099318-03

Grill Guard

1

4

101108-01

101108-01

Grill Guard Clip

2

5

099469-01

099469-02

Reflector Assembly

1

6

M15823-37

M15823-37

Screw Hex #8 x 1/4"

9

7

099059-03

503329

ODS/Pilot Assembly

1

7-1

098514-01

098514-01

Thermocouple

1

7-2

098594-01

098594-01

Ignitor Electrode

1

8

099884-01

099884-01

Burner Assembly

1

9

099056-04

099056-01

Injector

1

10

099390-01

099390-01

Tubing - Valve to burner

1

11

099387-05

099387-05

Pilot Tubing - Valve to pilot

1

12

099391-02

099391-02

Tubing - Regulator to valve

1

13

100829-01

100829-01

Control Valve

1

14

**

**

Cabinet Assembly

1

15

099415-17

099415-13

Gas Regulator

1

16

098303-02

098303-02

Screw, #6 x 5/16"

2

17

098508-01

098508-01

Valve Retainer Nut

1

18

099393-02

099393-02

Control Knob

1

19

M11084-26

M11084-26

Screw, #10 x 3/8"

2

20

099818-01

099818-01

Internal Tooth Washer

1

21

097159-04

097159-04

Piezo Ignitor

1

22

098271-03

098271-03

Ignitor Cable

1

 

 

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

 

 

 

 

 

099395-08

099395-08

Control Position Label

1

 

100642-02

100642-02

Assembly, Hardware

1

 

 

 

 

 

** Not a field replaceable part.

For more information, visit www.desatech.com

110720-01A

Image 25
Contents What to do if YOU Smell GAS VENT-FREE GAS HeaterSafety Information Table of ContentsUnpacking Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation AIR for CombustionVentilation AIR Ventilation Air From Inside BuildingInstallation Items InstallationCheck GAS Type Locating HeaterInstalling Two Mounting Screws Installing Heater to WallMarking Screw Locations Placing Heater On Mounting ScrewsInstalling Bottom Mounting Screw Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemOperating Heater Pressure Testing Heater Gas ConnectionsLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burner Only pilot stays litBurner Patterns To Select Heating LevelOFF Position Shown Thermostat Control Operation Inspecting BurnerPilot Flame Pattern Burner Flame Pattern Blue Flame ModelsCleaning Burner Pilot AIR Inlet Hole Cleaning MaintenanceBurner Flame Pattern Infrared Models ODS/PILOT and Burner OrificeObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at VP600BA VP5D VP10A VP1000BTA SpecificationsVN600BA VP600BA Pilot Illustrated Parts BreakdownKEY Part Number for VP600BA VN600BA Description QTY Parts ListVP10A VN10A KEY Part Number VP10A VN10A Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot KEY Part Number VP1000BTA VN1000BTA Description QTY Technical Service Replacement PartsService Publications AccessoryOwners Registration Form Postage Required Baltimore Electric Parts CentralsWarranty Information

VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, VP5D, VP1000BTA VN10A, VP10A specifications

The Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models represent a remarkable lineup in the realm of ventilation and heating solutions. Each of these models is designed with specific features and technologies that cater to diverse needs, enhancing comfort and efficiency in residential and commercial environments.

Starting with the VP600BA and VN600BA, these models provide robust heating capabilities paired with user-friendly interfaces. Highlighting energy efficiency, both units are engineered to minimize energy consumption while maximizing output. The VN1000BTA and VP1000BTA step up the game with advanced thermostatic controls. These models not only provide reliable heating but also enable precise temperature regulation, ensuring optimal comfort levels.

The VN10A and VP10A models are tailored for versatility, accommodating various space sizes without compromising performance. Equipped with high-efficiency burners, they deliver consistent warmth even in colder climates. The VN6D and VP5D models are compact yet powerful, making them perfect for smaller spaces or areas where installation flexibility is essential. Their lightweight design allows for easy maneuverability while maintaining high-temperature output.

Innovative technologies define these models, with features like electronic ignition systems that provide a hassle-free start-up experience. Many bear smart technology integration, allowing users to control settings remotely via smartphone applications. This level of interactivity signifies a growing trend in home automation, where convenience is key.

The aesthetics of these models cannot be overlooked. With sleek designs and customizable options, they seamlessly blend into a variety of interior decors, enhancing the overall ambiance of any space. The builds are also designed for durability, featuring corrosion-resistant materials that assure longevity.

In terms of safety, these models incorporate multiple redundancies, including automatic shut-off features and robust flame management systems. Hence, user peace of mind is guaranteed alongside effective heating solutions.

Overall, the Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models exemplify a harmonious balance of function, technology, and design, making them ideal choices for heating and ventilation in contemporary settings. Their array of features ensures each unit meets the specific demands of users, providing an energy-efficient and comfortable environment regardless of the application.