Desa VP10A, VP1000BTA VN10A Unpacking, Product Identification, Product Features, Local Codes

Page 3

SAFETY INFORMATION

Continued

4.If you smell gas

Shut off gas supply

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

If you cannot reach your gas supplier, call the fire department

5.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6.

6.Always run heater with control knob at LOW or HIGH locked positions (VP10A) or ON position (VP5D). Never set control knob between locked positions. Poor combustion may result.

7.Keep all air openings in the front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.

8.If heater shuts off, do not relight until you provide fresh, out- side air. If heater keeps shutting off, have it serviced.

9.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

10.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.

11.Do not use heater if any part has been under water. Immedi- ately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

12.Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

13.Operating heater above elevations of 4,500 feet could cause pilot outage.

14.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

15.Provide adequate clearances around air openings.

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

SAFETY INFORMATION

3

UNPACKING

PRODUCT IDENTIFICATION

 

PRODUCT FEATURES

 

LOCAL CODES

 

 

 

PRODUCT IDENTIFICATION

Piezo Ignitor

Piezo Ignitor

Button

Control Knob

Button

Control Knob

 

 

Grill

 

Guard

 

Glass

Burners

Panel

 

Front

 

Panel

 

Heater

 

Cabinet

 

Blue Flame Heater

Infrared Heater

Figure 1 - Vent-Free Gas Heater

 

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

For more information, visit www.desatech.com

110720-01A

Image 3
Contents What to do if YOU Smell GAS VENT-FREE GAS HeaterSafety Information Table of ContentsLocal Codes Product FeaturesUnpacking Product IdentificationConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building AIR for CombustionVentilation Ventilation AIRLocating Heater InstallationInstallation Items Check GAS TypePlacing Heater On Mounting Screws Installing Heater to WallInstalling Two Mounting Screws Marking Screw LocationsInstalling Bottom Mounting Screw Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Shutting Off Burner Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterBurner Patterns To Select Heating LevelOFF Position Shown Burner Flame Pattern Blue Flame Models Inspecting BurnerThermostat Control Operation Pilot Flame PatternODS/PILOT and Burner Orifice Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole Burner Flame Pattern Infrared ModelsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at VP600BA VP5D VP10A VP1000BTA SpecificationsVN600BA VP600BA Pilot Illustrated Parts BreakdownKEY Part Number for VP600BA VN600BA Description QTY Parts ListVP10A VN10A KEY Part Number VP10A VN10A Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot KEY Part Number VP1000BTA VN1000BTA Description QTY Accessory Replacement PartsTechnical Service Service PublicationsOwners Registration Form Postage Required Baltimore Electric Parts CentralsWarranty Information

VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, VP5D, VP1000BTA VN10A, VP10A specifications

The Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models represent a remarkable lineup in the realm of ventilation and heating solutions. Each of these models is designed with specific features and technologies that cater to diverse needs, enhancing comfort and efficiency in residential and commercial environments.

Starting with the VP600BA and VN600BA, these models provide robust heating capabilities paired with user-friendly interfaces. Highlighting energy efficiency, both units are engineered to minimize energy consumption while maximizing output. The VN1000BTA and VP1000BTA step up the game with advanced thermostatic controls. These models not only provide reliable heating but also enable precise temperature regulation, ensuring optimal comfort levels.

The VN10A and VP10A models are tailored for versatility, accommodating various space sizes without compromising performance. Equipped with high-efficiency burners, they deliver consistent warmth even in colder climates. The VN6D and VP5D models are compact yet powerful, making them perfect for smaller spaces or areas where installation flexibility is essential. Their lightweight design allows for easy maneuverability while maintaining high-temperature output.

Innovative technologies define these models, with features like electronic ignition systems that provide a hassle-free start-up experience. Many bear smart technology integration, allowing users to control settings remotely via smartphone applications. This level of interactivity signifies a growing trend in home automation, where convenience is key.

The aesthetics of these models cannot be overlooked. With sleek designs and customizable options, they seamlessly blend into a variety of interior decors, enhancing the overall ambiance of any space. The builds are also designed for durability, featuring corrosion-resistant materials that assure longevity.

In terms of safety, these models incorporate multiple redundancies, including automatic shut-off features and robust flame management systems. Hence, user peace of mind is guaranteed alongside effective heating solutions.

Overall, the Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models exemplify a harmonious balance of function, technology, and design, making them ideal choices for heating and ventilation in contemporary settings. Their array of features ensures each unit meets the specific demands of users, providing an energy-efficient and comfortable environment regardless of the application.