Desa VP10A, VP1000BTA VN10A installation manual To Select Heating Level, Burner Patterns

Page 12

12

OPERATING HEATER (Manual Control Infrared Models)

For Your Safety Read Before Lighting (Cont.)

Lighting Instructions

To Select Heating Level

To Turn Off Gas To Appliance

OPERATING HEATER

Continued

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information page 11, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, page 11, column 2. If you don’t smell gas, go to the next step.

5.Press in control knob, and turn counterclockwise to pilot position. Keep control knob pressed for five seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, refer to Troubleshooting, pages 17 through 19. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match, see Manual Lighting Procedure, page 13.

7.Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

Piezo Ignitor

 

Ignitor Electrode

 

Thermocouple

Pilot

Button

Control Knob

 

 

 

 

Burner

 

PILOT

OFF

 

 

 

 

 

 

IGNITOR

LOW

 

 

 

 

 

HIGH

 

 

TO SELECT HEATING LEVEL

WARNING: When running heater, set control knob at LOW or HIGH locked positions for double burner heater, or ON position for single burner heater.. Never set control knob between locked positions. Poor combustion and higher levels of carbon monox- ide may result.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Slightly press in control knob and turn

counterclockwise to the LOW or HIGH positions for double burner heater, or ON position for single burner heater.

IMPORTANT: Release downward pressure while turning con- trol knob. Control knob will lock at the desired position.

Control

Double

Control

Single

Knobs

Burners

Knob

Burner

 

 

OFF

 

 

 

PILOT

 

 

 

ON

 

 

 

OFF

 

Figure 21 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Figure 19 - Control Knob In

Figure 20 - Pilot, Infrared Turn control knob clockwise to the PILOT position.

The OFF Position

Heaters

For morevisit www..com

110720-01A

Image 12
Contents VENT-FREE GAS Heater What to do if YOU Smell GASTable of Contents Safety InformationProduct Features UnpackingProduct Identification Local CodesAIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceAIR for Combustion VentilationVentilation AIR Ventilation Air From Inside BuildingInstallation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Installing Two Mounting ScrewsMarking Screw Locations Placing Heater On Mounting ScrewsConnecting to GAS Supply Installing Bottom Mounting ScrewPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceShutting Off Heater Shutting Off Burner Only pilot stays litTo Select Heating Level Burner PatternsOFF Position Shown Inspecting Burner Thermostat Control OperationPilot Flame Pattern Burner Flame Pattern Blue Flame ModelsCleaning Maintenance Cleaning Burner Pilot AIR Inlet HoleBurner Flame Pattern Infrared Models ODS/PILOT and Burner OrificeTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Specifications VP600BA VP5D VP10A VP1000BTAIllustrated Parts Breakdown VN600BA VP600BA PilotParts List KEY Part Number for VP600BA VN600BA Description QTYVP10A VN10A KEY Part Number VP10A VN10A Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot KEY Part Number VP1000BTA VN1000BTA Description QTY Replacement Parts Technical ServiceService Publications AccessoryOwners Registration Form Postage Required Parts Centrals Baltimore ElectricWarranty Information

VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, VP5D, VP1000BTA VN10A, VP10A specifications

The Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models represent a remarkable lineup in the realm of ventilation and heating solutions. Each of these models is designed with specific features and technologies that cater to diverse needs, enhancing comfort and efficiency in residential and commercial environments.

Starting with the VP600BA and VN600BA, these models provide robust heating capabilities paired with user-friendly interfaces. Highlighting energy efficiency, both units are engineered to minimize energy consumption while maximizing output. The VN1000BTA and VP1000BTA step up the game with advanced thermostatic controls. These models not only provide reliable heating but also enable precise temperature regulation, ensuring optimal comfort levels.

The VN10A and VP10A models are tailored for versatility, accommodating various space sizes without compromising performance. Equipped with high-efficiency burners, they deliver consistent warmth even in colder climates. The VN6D and VP5D models are compact yet powerful, making them perfect for smaller spaces or areas where installation flexibility is essential. Their lightweight design allows for easy maneuverability while maintaining high-temperature output.

Innovative technologies define these models, with features like electronic ignition systems that provide a hassle-free start-up experience. Many bear smart technology integration, allowing users to control settings remotely via smartphone applications. This level of interactivity signifies a growing trend in home automation, where convenience is key.

The aesthetics of these models cannot be overlooked. With sleek designs and customizable options, they seamlessly blend into a variety of interior decors, enhancing the overall ambiance of any space. The builds are also designed for durability, featuring corrosion-resistant materials that assure longevity.

In terms of safety, these models incorporate multiple redundancies, including automatic shut-off features and robust flame management systems. Hence, user peace of mind is guaranteed alongside effective heating solutions.

Overall, the Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models exemplify a harmonious balance of function, technology, and design, making them ideal choices for heating and ventilation in contemporary settings. Their array of features ensures each unit meets the specific demands of users, providing an energy-efficient and comfortable environment regardless of the application.