Desa VP10A, VP1000BTA VN10A Check GAS Type, Installation Items, Locating Heater

Page 6

6

INSTALLATION

Check Gas Type

Installation Items

Locating Heater

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in- stall heater. Follow all local codes.

CHECK GAS TYPE

Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

for propane/LP gas, external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

sediment trap

tee joint

pipe wrench

for natural gas, test gauge connection*

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessory, page 28.

LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clear- ances from floor, ceiling, and joining wall.

WARNING: Never install the heater

in a bathroom (10,000 Btu/hr only. 6,000 Btu/hr mod- els are allowed in a bathroom. Check local codes.)

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Al- though this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving vehicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

 

CEILING

6" Blueflame

36"

Minimum

8" Plaque

 

Minimum

 

From

 

Sides Of

 

Heater

 

 

Right

Left

Side

Side

 

3" Minimum To Top

Surface Of Carpeting,

Tile Or Other

Combustible Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

For morevisit www..com

110720-01A

Image 6
Contents VENT-FREE GAS Heater What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Product FeaturesUnpacking Local CodesDetermining FRESH-AIR Flow for Heater Location AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceVentilation AIR AIR for CombustionVentilation Ventilation Air From Inside BuildingCheck GAS Type InstallationInstallation Items Locating HeaterMarking Screw Locations Installing Heater to WallInstalling Two Mounting Screws Placing Heater On Mounting ScrewsConnecting to GAS Supply Installing Bottom Mounting ScrewPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Shutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burner Only pilot stays litTo Select Heating Level Burner PatternsOFF Position Shown Pilot Flame Pattern Inspecting BurnerThermostat Control Operation Burner Flame Pattern Blue Flame ModelsBurner Flame Pattern Infrared Models Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole ODS/PILOT and Burner OrificeTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Specifications VP600BA VP5D VP10A VP1000BTAIllustrated Parts Breakdown VN600BA VP600BA PilotParts List KEY Part Number for VP600BA VN600BA Description QTYVP10A VN10A KEY Part Number VP10A VN10A Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot KEY Part Number VP1000BTA VN1000BTA Description QTY Service Publications Replacement PartsTechnical Service AccessoryOwners Registration Form Postage Required Parts Centrals Baltimore ElectricWarranty Information

VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, VP5D, VP1000BTA VN10A, VP10A specifications

The Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models represent a remarkable lineup in the realm of ventilation and heating solutions. Each of these models is designed with specific features and technologies that cater to diverse needs, enhancing comfort and efficiency in residential and commercial environments.

Starting with the VP600BA and VN600BA, these models provide robust heating capabilities paired with user-friendly interfaces. Highlighting energy efficiency, both units are engineered to minimize energy consumption while maximizing output. The VN1000BTA and VP1000BTA step up the game with advanced thermostatic controls. These models not only provide reliable heating but also enable precise temperature regulation, ensuring optimal comfort levels.

The VN10A and VP10A models are tailored for versatility, accommodating various space sizes without compromising performance. Equipped with high-efficiency burners, they deliver consistent warmth even in colder climates. The VN6D and VP5D models are compact yet powerful, making them perfect for smaller spaces or areas where installation flexibility is essential. Their lightweight design allows for easy maneuverability while maintaining high-temperature output.

Innovative technologies define these models, with features like electronic ignition systems that provide a hassle-free start-up experience. Many bear smart technology integration, allowing users to control settings remotely via smartphone applications. This level of interactivity signifies a growing trend in home automation, where convenience is key.

The aesthetics of these models cannot be overlooked. With sleek designs and customizable options, they seamlessly blend into a variety of interior decors, enhancing the overall ambiance of any space. The builds are also designed for durability, featuring corrosion-resistant materials that assure longevity.

In terms of safety, these models incorporate multiple redundancies, including automatic shut-off features and robust flame management systems. Hence, user peace of mind is guaranteed alongside effective heating solutions.

Overall, the Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models exemplify a harmonious balance of function, technology, and design, making them ideal choices for heating and ventilation in contemporary settings. Their array of features ensures each unit meets the specific demands of users, providing an energy-efficient and comfortable environment regardless of the application.