Desa VP1000BTA VN10A, VP10A Troubleshooting, Observed Problem Possible Cause Remedy

Page 16

16

TROUBLESHOOTING

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

When ignitor button is pressed, there is no

1.

Ignitor electrode positioned wrong

1.

Replace pilot assembly

 

spark at ODS/pilot

2.

Ignitor electrode broken

2.

Replace pilot assembly

 

 

3.

Ignitor electrode not connected to igni-

3.

Reconnect ignitor cable

 

 

 

tor cable

 

 

 

 

4.

Ignitor cable pinched or wet

4.

Free ignitor cable if pinched by any

 

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

 

5.

Piezo ignitor nut is loose

5.

Tighten nut holding piezo ignitor to

 

 

 

 

 

heater cabinet. Nut is located inside

 

 

 

 

 

heater cabinet at top

 

 

6.

Broken ignitor cable

6.

Replace ignitor cable

 

 

7.

Bad piezo ignitor

7.

Replace piezo ignitor

 

 

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

 

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

 

PILOT position

 

position

 

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

 

Repeat igniting operation until air is re-

 

 

 

 

 

moved

 

 

5.

Depleted gas supply (propane/LP only)

5.

Contact local propane/LP gas company

 

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

 

Maintenance, page 15) or replace ODS/

 

 

 

 

 

pilot assembly

 

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

 

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

 

knob pressed in 30 seconds

 

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

 

4.

Thermocouple connection loose at con-

4.

Hand tighten until snug, then tighten 1/4

 

 

 

trol valve

 

turn more

 

 

5.

Pilot flame not touching thermocouple,

5.

A) Contact local natural or propane/LP

 

 

 

which allows thermocouple to cool,

 

gas company

 

 

 

causing pilot flame to go out. This prob-

 

B) Clean ODS/pilot (see Cleaning and

 

 

 

lem could be caused by one or both of

 

Maintenance, page 15) or replace ODS/

 

 

 

the following:

 

pilot assembly

 

 

 

A) Low gas pressure

 

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

 

7.

Control valve damaged

7.

Replace control valve

For morevisit www..com

110720-01A

Image 16
Contents VENT-FREE GAS Heater What to do if YOU Smell GASTable of Contents Safety InformationProduct Features UnpackingProduct Identification Local CodesAIR for Combustion and Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceAIR for Combustion VentilationVentilation AIR Ventilation Air From Inside BuildingInstallation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Installing Two Mounting ScrewsMarking Screw Locations Placing Heater On Mounting ScrewsConnecting to GAS Supply Installing Bottom Mounting ScrewPressure Testing Gas Supply Piping System Checking GAS ConnectionsOperating Heater Pressure Testing Heater Gas ConnectionsLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceShutting Off Heater Shutting Off Burner Only pilot stays litTo Select Heating Level Burner PatternsOFF Position Shown Inspecting Burner Thermostat Control OperationPilot Flame Pattern Burner Flame Pattern Blue Flame ModelsCleaning Maintenance Cleaning Burner Pilot AIR Inlet HoleBurner Flame Pattern Infrared Models ODS/PILOT and Burner OrificeTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Specifications VP600BA VP5D VP10A VP1000BTAIllustrated Parts Breakdown VN600BA VP600BA PilotParts List KEY Part Number for VP600BA VN600BA Description QTYVP10A VN10A KEY Part Number VP10A VN10A Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot KEY Part Number VP1000BTA VN1000BTA Description QTY Replacement Parts Technical ServiceService Publications AccessoryOwners Registration Form Postage Required Parts Centrals Baltimore ElectricWarranty Information

VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, VP5D, VP1000BTA VN10A, VP10A specifications

The Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models represent a remarkable lineup in the realm of ventilation and heating solutions. Each of these models is designed with specific features and technologies that cater to diverse needs, enhancing comfort and efficiency in residential and commercial environments.

Starting with the VP600BA and VN600BA, these models provide robust heating capabilities paired with user-friendly interfaces. Highlighting energy efficiency, both units are engineered to minimize energy consumption while maximizing output. The VN1000BTA and VP1000BTA step up the game with advanced thermostatic controls. These models not only provide reliable heating but also enable precise temperature regulation, ensuring optimal comfort levels.

The VN10A and VP10A models are tailored for versatility, accommodating various space sizes without compromising performance. Equipped with high-efficiency burners, they deliver consistent warmth even in colder climates. The VN6D and VP5D models are compact yet powerful, making them perfect for smaller spaces or areas where installation flexibility is essential. Their lightweight design allows for easy maneuverability while maintaining high-temperature output.

Innovative technologies define these models, with features like electronic ignition systems that provide a hassle-free start-up experience. Many bear smart technology integration, allowing users to control settings remotely via smartphone applications. This level of interactivity signifies a growing trend in home automation, where convenience is key.

The aesthetics of these models cannot be overlooked. With sleek designs and customizable options, they seamlessly blend into a variety of interior decors, enhancing the overall ambiance of any space. The builds are also designed for durability, featuring corrosion-resistant materials that assure longevity.

In terms of safety, these models incorporate multiple redundancies, including automatic shut-off features and robust flame management systems. Hence, user peace of mind is guaranteed alongside effective heating solutions.

Overall, the Desa VP600BA, VN600BA, VN1000BTA, VP1000BTA, VN10A, VP10A, VN6D, and VP5D models exemplify a harmonious balance of function, technology, and design, making them ideal choices for heating and ventilation in contemporary settings. Their array of features ensures each unit meets the specific demands of users, providing an energy-efficient and comfortable environment regardless of the application.