Quadra-Fire SAPPHIRE-MBK, SAPPHIRE-D-MBK Glass Door Assembly Optional Blower Installation

Page 32

J. Glass Door Assembly

K. Optional Blower Installation

Pull Latch Forward

Lift toward you and away from appliance

Figure 8.16 Turn the appliance OFF and let it cool down before replacing the inner glass door assembly.

Remove the glass door assembly by opening latches at the bottom front of the appliance, on both the left and right sides. Lift towards you and away from the appliance.

From The Kit You Will Need: Blower motor; wire harness; rheostat; rheostat nut; knob; screws; and 1 zip-tie.

From The Stove Component Bag You Will Need: Snap disc bracket and 5/16 in. nut.

Tools Required: #2 Phillips head bit; hand drill; 11/16 in. wrench; and a 5/16 in. wrench.

Attach with 4 Screws

Figure 8.17 Turn off gas supply (if gas is connected), and remove the rear shield. Remove the blower from pack- aging. Place the blower under the appliance. Attach the blower from the front with four screws to the blower bracket.

Secure with

Install Snap Disc

through the Bracket

5/16 in. nut

Replace with a new glass door assembly.

NOTE: The glass, gasketing, and frame must be replaced as a complete unit as supplied by the manufacturer.

Do NOT use substitute material.

CAUTION

Handle glass assembly with care.

Inspect the gasket to ensure it is undamaged.

Inspect the glass for cracks, chips or scratches.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass door removed, cracked, broken or scratched.

Replace glass assembly as a complete assembly.

Figure 8.18 Install the snap disc in the bracket. Attach the bracket to the firebox with a 5/16 in. wrench.

Figure 8.19 Connect the electrical connectors to the snap disc.

32

Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11

Image 32
Contents Do Discardnot What to do if you smell gasDo not Discard this Manual Serial Number Model Name Mfg DateTable of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Design & Installation Considerations Getting StartedTools and Supplies Needed Inspect Appliance & ComponentsDesign Purposes only Selecting Appliance LocationClearances to Combustibles 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting Guidelines for Horizontal RunsType a Up and Out Installation Type B Straight Out InstallationType C 45 Elbow in Corner Installation Horizontal Termination203mm Step Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type a Type C Up & Out Installation Type D Hearth MountType a & B Co-Axial to Co-Linear Fire Risk Explosion Risk Retro Connector Installation Propane LP Natural Gas Gas InformationFuel Conversions Converting to LP GasValve Regulator Replacement Screws Rubber Gasket Identification Label FGas Pressures Gas Connection PressureHigh Altitude Installations Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceWire Size Max. Length Electrical InformationSwitch Standing Pilot Ignition System WiringIgnitor Valve Appliance Setup Accessories Remove Shipping Materials Top to Rear Vent ConversionLeg Leveling System Baffle Installation/AdjustmentBrick Installation Embers Positioning the LogsMineral Wool Glass Door Assembly Optional Blower Installation Do not use substitute materialBlower Shutter Adjustment Controls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram Mm inner pipe 6-5/8 in mm outer pipeVent Components List DescriptionSimpson Dura-VentHHT SLP SimpsonDescription Dura-Vent Termination Caps & KitsLog Set Assembly Service PartsPart number list on following 19 18At Depot StockedDescription Comments Part Number BK-GASLPK-30K StockedNGK-30K Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information