Quadra-Fire SAPPHIRE-MBK, SAPPHIRE-D-MBK, SAPPHIRE-D-PMH Description Comments Part Number, Bk-Gas

Page 48

D. Service Parts

 

SAPPHIRE-D

 

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

 

 

 

Stocked

 

parts for your appliance please provide model number and serial number. All parts listed

 

 

in this manual may be ordered from an authorized dealer.

 

 

at Depot

 

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

 

 

 

CSB

SRV7055-105CSB

 

23

Door, Right

CWL

SRV7055-105CWL

 

MBK

SRV7055-105MBK

 

 

 

 

 

 

 

 

PMH

SRV7055-105PMH

 

 

24

Cast Front Hook

 

SRV7055-110

 

 

25

Glass Retainer

 

7010-121

 

 

26

Burner Plate Assembly

 

7010-022

 

 

27

Pilot Spacer

 

7031-256

 

 

28

Burner With Neck

 

SRV7010-025

Y

 

29

Log Support Rear

 

7010-134

 

 

30

Draw Latch A1-10-501-10

 

229-0640

Y

31

.1 31

.2 31

.3

 

31

.4

 

31

31.1

Pilot, 3 Flame, Flush Mount

 

230-1781

Y

31.2

Shutter Assembly

 

SRV7010-027

Y

31.3

Bulkhead

 

26457

Y

31.4

Bulkhead Stop

 

474-0090

 

32

Blower Bracket

 

7010-146

 

33

Blower Assembly

 

BK-GAS

 

34

Blower Bracket Rear

 

7009-103

 

35

Adapter Gasket

 

460-0610

 

36

Gasket, Cover Plate

 

7010-160

 

37

Back Shield Support

 

SRV7055-115

 

38

Valve, Gas, NG

 

230-0710

Y

39

Set Collar 1/4

 

229-0750

 

40

Adapter, Valve Extension

 

450-6330

 

41

Back Shield Lower

 

SRV7055-112

 

42

Cast Retainer Rear

 

SRV7055-109

 

43

Control Rod

 

455-0340

 

44

Back Shield Upper

 

SRV7055-111

 

45

Knob, Rheostat (Black)

Qty 2 req

100-512

Y

46

Switch, Rocker, On/Off

 

230-0730

Y

47

Piezo Ignitor

 

291-513

Y

Additional service parts on following page

48

Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11

Image 48
Contents What to do if you smell gas Do not Discard this ManualDo Discardnot Serial Number Model Name Mfg DateTable of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Design & Installation Considerations Getting StartedTools and Supplies Needed Inspect Appliance & ComponentsSelecting Appliance Location Clearances to CombustiblesDesign Purposes only 4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting Guidelines for Horizontal RunsType a Up and Out Installation Type B Straight Out InstallationType C 45 Elbow in Corner Installation Horizontal Termination203mm Step Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type C Up & Out Installation Type D Hearth Mount Type a & B Co-Axial to Co-LinearExisting Masonry Chimney Type a Fire Risk Explosion Risk Retro Connector Installation Propane LP Natural Gas Gas InformationFuel Conversions Converting to LP GasValve Regulator Replacement Screws Rubber Gasket Identification Label FGas Pressures Gas Connection PressureHigh Altitude Installations Check for GAS LeaksRecommendation for Wire Connecting to the ApplianceWire Size Max. Length Electrical InformationSwitch Standing Pilot Ignition System WiringIgnitor ValveAppliance Setup AccessoriesRemove Shipping Materials Top to Rear Vent ConversionBaffle Installation/Adjustment Brick InstallationLeg Leveling System Positioning the Logs Mineral WoolEmbers Glass Door Assembly Optional Blower Installation Do not use substitute materialBlower Shutter Adjustment Operating Instructions Before Lighting ApplianceControls For Your Safety Read Before Lighting Lighting ApplianceFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram Mm inner pipe 6-5/8 in mm outer pipeVent Components List DescriptionSimpson Dura-VentHHT SLP SimpsonDescription Dura-Vent Termination Caps & KitsLog Set Assembly Service PartsPart number list on following 19 18At Depot StockedDescription Comments Part Number BK-GASStocked NGK-30KLPK-30K Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information

SAPPHIRE-D-CSB, SAPPHIRE-D-PMH, SAPPHIRE-MBK, SAPPHIRE-D-MBK specifications

The Quadra-Fire Sapphire series of fireplaces, which includes the Sapphire-D-PMH, Sapphire-D-CSB, Sapphire-D-MBK, and Sapphire-MBK models, epitomizes modern heating technology combined with elegant design. These units are meticulously engineered to enhance both efficiency and aesthetics, making them perfect additions to contemporary living spaces.

One of the standout features of the Sapphire series is its advanced combustion technology. The fireplaces utilize a patented Clean Burn technology. This innovation ensures that the combustion process is as efficient as possible, resulting in reduced emissions and maximizing heat output. With lower particulate emissions, these models not only provide warmth but do so in an environmentally conscious manner.

In terms of performance, the Sapphire fireplaces are designed to deliver consistent and radiant heat. With their powerful heating capabilities, they can warm up large areas, making them suitable for homes of various sizes. The efficient design helps to distribute heat evenly throughout a room, eliminating cold spots and ensuring comfort in all corners of your living space.

The design aesthetics of the Sapphire series is equally impressive. The models feature a sleek, modern design complemented by a large viewing area, allowing for an unobstructed view of the mesmerizing flames. The glass is designed to remain clean for longer periods, thanks to the sophisticated airflow management system that directs air over the glass surfaces, reducing soot buildup.

Customization options are another notable characteristic of the Sapphire series. Homeowners can choose from various finishes and styles to match their home’s decor. The units are available in both traditional and contemporary designs, allowing for versatility in different architectural settings.

The Sapphire-D-PMH model is equipped with a programmable thermostat for added convenience and efficiency. This technology allows users to set the desired temperature, ensuring that their space remains comfortable without unnecessary manual adjustments.

On the other hand, the Sapphire-D-CSB model features an innovative fuel management system that optimally uses wood fuel for extended burn times. This means less frequent refueling and more time spent enjoying the warmth and ambiance the fireplace provides.

The Sapphire-D-MBK and Sapphire-MBK models are designed with durability and longevity in mind. Each unit is constructed from high-quality materials that are built to withstand extreme temperatures while maintaining structural integrity over time.

In summary, the Quadra-Fire Sapphire series combines advanced technology, unique design, and high efficiency. With features like Clean Burn technology, customizable options, and smart fuel management systems, the Sapphire fireplaces offer not just heat, but a stylish centerpiece for modern homes.