Quadra-Fire SAPPHIRE-D-CSB, SAPPHIRE-MBK Selecting Appliance Location, Clearances to Combustibles

Page 7

3

Appliance Location and Clearances

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

WARNING

 

· Illustrations reflect typical installations and are FOR

 

 

 

 

 

Fire Risk

DESIGN PURPOSES ONLY.

 

· Illustrations/diagrams are not drawn to scale.

 

Provide adequate clearance:

 

Around air openings

 

· Actual installation may vary due to individual design

 

To combustibles

preference.

 

For service access

Locate appliance away from traffic areas.

A. Selecting Appliance Location

When selecting a location for your appliance it is important to consider the required clearances to walls (see Figure 3.1).

NOTE: For actual appliance dimensions refer to Section 12.

WARNING

Fire Risk.

Locate and install appliance to all clearance specifications in manual.

B. Clearances to Combustibles

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

A

A

B

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

A

E

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

A

B

C

D

E

F

 

 

Sapphire Gas Stove

Inches

6

6

3

54

36

34

 

 

 

 

Millimeters

152

152

76

1372

914

1016

 

Figure 3.1

 

 

 

 

 

 

 

 

 

 

It is permissible to place the appliance on carpet.

CAUTION

Some carpet materials may be sensitive to radiant heat from the appliance causing discoloration or odor.

NOTE: Flooring beneath appliance may reach 90 degrees plus room ambient temperature. Check with flooring manufacturer for maximum temperature allowed on flooring surfaces.

WARNING

Fire Risk.

Odor Risk.

Tipping Risk

Install appliance on a stable, level platform/ floor strong enough to support appliance without tipping.

USE wood flooring, ceramic tile, brick hearth or high pressure laminate flooring applied directly over the sub-flooring material.

Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11

7

Image 7
Contents Do not Discard this Manual What to do if you smell gasDo Discardnot Mfg Date Serial Number Model NameTable of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsGetting Started Tools and Supplies NeededClearances to Combustibles Selecting Appliance LocationDesign Purposes only Vent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsVenting Guidelines for Horizontal Runs How to Use the Vent GraphHorizontal Termination Type a Up and Out InstallationType B Straight Out Installation Type C 45 Elbow in Corner Installation203mm Step Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a & B Co-Axial to Co-Linear Type C Up & Out Installation Type D Hearth MountExisting Masonry Chimney Type a Fire Risk Explosion Risk Retro Connector Converting to LP Gas Installation Propane LP Natural GasGas Information Fuel ConversionsScrews Rubber Gasket Identification Label F Valve Regulator ReplacementPressure Gas Pressures Gas ConnectionCheck for GAS Leaks High Altitude InstallationsElectrical Information Recommendation for WireConnecting to the Appliance Wire Size Max. LengthValve SwitchStanding Pilot Ignition System Wiring IgnitorTop to Rear Vent Conversion Appliance SetupAccessories Remove Shipping MaterialsBrick Installation Baffle Installation/AdjustmentLeg Leveling System Mineral Wool Positioning the LogsEmbers Do not use substitute material Glass Door Assembly Optional Blower InstallationBlower Shutter Adjustment Before Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramMm inner pipe 6-5/8 in mm outer pipe Vent Components DiagramDura-Vent Vent Components ListDescription SimpsonTermination Caps & Kits HHT SLPSimpson Description Dura-Vent19 18 Log Set AssemblyService Parts Part number list on followingStocked At DepotBK-GAS Description Comments Part NumberNGK-30K StockedLPK-30K Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Contact Information

SAPPHIRE-D-CSB, SAPPHIRE-D-PMH, SAPPHIRE-MBK, SAPPHIRE-D-MBK specifications

The Quadra-Fire Sapphire series of fireplaces, which includes the Sapphire-D-PMH, Sapphire-D-CSB, Sapphire-D-MBK, and Sapphire-MBK models, epitomizes modern heating technology combined with elegant design. These units are meticulously engineered to enhance both efficiency and aesthetics, making them perfect additions to contemporary living spaces.

One of the standout features of the Sapphire series is its advanced combustion technology. The fireplaces utilize a patented Clean Burn technology. This innovation ensures that the combustion process is as efficient as possible, resulting in reduced emissions and maximizing heat output. With lower particulate emissions, these models not only provide warmth but do so in an environmentally conscious manner.

In terms of performance, the Sapphire fireplaces are designed to deliver consistent and radiant heat. With their powerful heating capabilities, they can warm up large areas, making them suitable for homes of various sizes. The efficient design helps to distribute heat evenly throughout a room, eliminating cold spots and ensuring comfort in all corners of your living space.

The design aesthetics of the Sapphire series is equally impressive. The models feature a sleek, modern design complemented by a large viewing area, allowing for an unobstructed view of the mesmerizing flames. The glass is designed to remain clean for longer periods, thanks to the sophisticated airflow management system that directs air over the glass surfaces, reducing soot buildup.

Customization options are another notable characteristic of the Sapphire series. Homeowners can choose from various finishes and styles to match their home’s decor. The units are available in both traditional and contemporary designs, allowing for versatility in different architectural settings.

The Sapphire-D-PMH model is equipped with a programmable thermostat for added convenience and efficiency. This technology allows users to set the desired temperature, ensuring that their space remains comfortable without unnecessary manual adjustments.

On the other hand, the Sapphire-D-CSB model features an innovative fuel management system that optimally uses wood fuel for extended burn times. This means less frequent refueling and more time spent enjoying the warmth and ambiance the fireplace provides.

The Sapphire-D-MBK and Sapphire-MBK models are designed with durability and longevity in mind. Each unit is constructed from high-quality materials that are built to withstand extreme temperatures while maintaining structural integrity over time.

In summary, the Quadra-Fire Sapphire series combines advanced technology, unique design, and high efficiency. With features like Clean Burn technology, customizable options, and smart fuel management systems, the Sapphire fireplaces offer not just heat, but a stylish centerpiece for modern homes.