Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

Direction of pipe

 

 

 

• Left (B)

 

 

• Underside_right (C)

A

B

• Rear_right or left (D)

D

D

C

 

 

 

1.Disassemble the cover panel as described in page 37~38.

2.Remove the Hanger plate from the indoor unit.

(1)Unscrew 2 screws that fixes the Hanger plate to the indoor unit.

(2)Push the hooks (on the bottom part of the indoor unit) up to release the installation plate from the hooks that holds it.

(3)Pull the installation plate to release it completely from the indoor unit.

Screw

3.Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards.

Pipe hole (Ø65 mm)

 

Pipe hole (Ø65 mm)

A

 

 

D

A

D

B

 

 

C

B

C

 

 

 

(Unit : mm)

 

Model

A

B

C

D

• Make sure to drill only one hole after choosing

 

 

 

 

 

09/12

36

190

81

36

the direction of the pipe.

18/24/30

33

110

110

33

 

4. Fix the indoor unit.

If you fix the indoor unit on a wall

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

• If you mount the plate to a concrete wall using plastic anchors, make sure that gaps

Plastic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anchor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between the wall and the plate, created by projected anchor, is less than 20 mm.

 

<20 mm

 

 

 

 

 

 

 

 

If you fix the indoor unit on a window frame

(1)Determine the positions of the wooden uprights to be attached to the window frame.

(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

(3)Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board

(1)Use stud finder to find out locations of the studs.

(2)Fix the plate hanger on two studs.

English-36

Wall

A3050 TV_IB&IM_DB68-04043A-01_EN.indd 36

2014/8/15 15:44:33

Image 36 Contents
A3050 TVIB&IMDB68-04043A-01EN.indd 2014/8/15 Features of your new air conditioner Contents Safety precautions English-4For Power Supply English-5For Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesEnglish-10 Checking the power consumption English-11Checking the name of the parts Main partsDisplay English-12Checking the remote controller Remote controller buttonsEnglish-13 Remote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Adjusting the air flow direction Vertical air flowHorizontal air flow ARHSF Horizontal air flow ARHSSUsing the Fast function Using the Comfort functionEnglish-18 When the air conditioner is on and in cool/heat mode ModeEnglish-19 Setting the On/Off timer Press the On Timer or Off Timer button to set the timePress the Set/Cancel button to activate it on Additional options available in On timer modeUsing the Auto Clean function When the air conditioner is turned onEnglish-21 If the air conditioner is on If the air conditioner is offUsing the Single User function Using the Virus Doctor functionEnglish-22 Using the Quiet function You can reduce the noise generated from an indoor unitCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger English-24Cleaning the air filter Removing the Air filterEnglish-25 Dry the Air filter in a ventilated areaReassembling the Air filter English-26Top of the Air filter into the the main body..  Maintaining the air conditioner English-27Troubleshooting Air conditionerEnglish-28 Adjustment is not Check if you press the Set/Cancel button on the remoteCheck that there are strong lighting apparatus near the air Water is droppingInstalling the unit General informationEnglish-30 Choosing the installation location Power supply line, fuse or circuit breaker a place where the air filter can be replaced easily Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-32 When installing more than 1 outdoor unit English-33Top view Side view Accessories Accessories in the indoor unit caseEnglish-34 Unit mmAccessories in the outdoor unit case Optional accessoriesTools required for installation General Tools Tools for test operationsFixing the installation plate English-36Fix the indoor unit If you fix the indoor unit on a wall If you fix the indoor unit on a window frameThis QR code for detail video of indoor unit installation Assembling the hanger screwRemoving the screws English-37Assembling the Cover panel After mounting the indoor unit English-38Connecting the assembly cable Cable specificationConnecting the cable English-39Each wire is labeled with the corresponding terminal number English-40Close the cover panel English-41 Evacuating the indoor unit Cutting or extending the pipeEnglish-42 Unscrew the caps at the end of each pipeEnglish-43 Put a flare nut slightly into the pipe and modify the flareDepth a Drain hose installation English-44English-45 Evacuating the connected pipes English-46Connect a drain hose to the drain plug Ensure that condensation draining is adequateAdding Refrigerant English-47Outer Torque If you use a pipe longer than 7.5 mEnglish-48 Please fill in with indelible ink the factory refrigerant charge of the product 1975Performing the gas leak tests English-49Outdoor unit installed on the wall by rack Ensure the wall will be able to suspend the weight of rackFixing the outdoor unit in place English-50Smart Install mode English-51English-52  Off / Blinking / OnFinal check and trial operation English-53How to connect your extended power cables English-54Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-55 A3050 TVIB&IMDB68-04043A-01EN.indd 2014/8/15 Air Conditioner Register your product at DB68-04043A-01