Samsung AR30HSFSSWKNTV Assembling the Cover panel After mounting the indoor unit, English-38

Page 38
Disassembling/Assembling the Cover panel for indoor unit installation
Removing the Cover panel (Before mounting the indoor unit)
The bottom panel fits the main body using the side, center, and bottom hooks as shown.. Unlock the side hooks first, and then unlock the center and bottom hooks..
Check the location of the hooks before removing the cover panel.. ffLocation of the hooks on the central part
Number and location of the hooks
Side
hooks

Center hooks

Bottom hooks

ffRemoving the hooks on the side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Center hook

 

Bottom hook

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For specific Hook location and quantity, please refer to cover panel with indicating arrows based on physical goods..

ffRemoving the hooks on the central part

② ①

Caution (fragile)

-- Gently press the both side of the cover panel inwards () and release the hooks on both sides()..

Caution (fragile) -- Use both hands

-- Release each hook by pushing it up at an angle..

Assembling the Cover panel (After mounting the indoor unit)

To assemble the Cover panel, proceed in reverse order of disassembling..

Use both hands for assembling and be extra careful not to damage the pipes and drain hose..

Lock the side, center, and bottom hooks in this sequence.. Tighten the bottom panel with the screws, and close the screw holes with their cap..

<Lock the side hook>

<Lock the bottom hook>

<Fasten the screw>

<Assemble the Cap screw>

English-38

A3050 TV_IB&IM_DB68-04043A-01_EN.indd 38

2014/8/15 15:44:36

Image 38 Contents
A3050 TVIB&IMDB68-04043A-01EN.indd 2014/8/15 Features of your new air conditioner Contents Safety precautions English-4For Power Supply English-5For Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Checking the power consumption English-11Display Checking the name of the partsMain parts English-12English-13 Checking the remote controllerRemote controller buttons Storing the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Horizontal air flow ARHSF Adjusting the air flow directionVertical air flow Horizontal air flow ARHSSEnglish-18 Using the Fast functionUsing the Comfort function English-19 When the air conditioner is on and in cool/heat modeMode Press the Set/Cancel button to activate it on Setting the On/Off timerPress the On Timer or Off Timer button to set the time Additional options available in On timer modeEnglish-21 Using the Auto Clean functionWhen the air conditioner is turned on If the air conditioner is on If the air conditioner is offEnglish-22 Using the Single User functionUsing the Virus Doctor function Using the Quiet function You can reduce the noise generated from an indoor unitCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit English-24English-25 Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaTop of the Air filter into the the main body..  Reassembling the Air filterEnglish-26 Maintaining the air conditioner English-27English-28 TroubleshootingAir conditioner Check that there are strong lighting apparatus near the air Adjustment is notCheck if you press the Set/Cancel button on the remote Water is droppingEnglish-30 Installing the unitGeneral information  a place where the air filter can be replaced easily Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitEnglish-32 Where sulfide gas existsOutdoor Unit Top view Side view When installing more than 1 outdoor unitEnglish-33 English-34 AccessoriesAccessories in the indoor unit case Unit mmTools required for installation General Tools Accessories in the outdoor unit caseOptional accessories Tools for test operationsFix the indoor unit If you fix the indoor unit on a wall Fixing the installation plateEnglish-36 If you fix the indoor unit on a window frameRemoving the screws This QR code for detail video of indoor unit installationAssembling the hanger screw English-37Assembling the Cover panel After mounting the indoor unit English-38Connecting the cable Connecting the assembly cableCable specification English-39Close the cover panel Each wire is labeled with the corresponding terminal numberEnglish-40 English-41 English-42 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeDepth a English-43Put a flare nut slightly into the pipe and modify the flare Drain hose installation English-44English-45 Connect a drain hose to the drain plug Evacuating the connected pipesEnglish-46 Ensure that condensation draining is adequateOuter Torque Adding RefrigerantEnglish-47 If you use a pipe longer than 7.5 m the factory refrigerant charge of the product English-48Please fill in with indelible ink 1975Performing the gas leak tests English-49Fixing the outdoor unit in place Outdoor unit installed on the wall by rackEnsure the wall will be able to suspend the weight of rack English-50Smart Install mode English-51English-52  Off / Blinking / OnFinal check and trial operation English-53Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-54 After tube contraction work is completed, wrap it withEnglish-55 A3050 TVIB&IMDB68-04043A-01EN.indd 2014/8/15 Air Conditioner Register your product at DB68-04043A-01