Quadra-Fire CB1200 Reference Materials, CB 200 Pellet Stove, Component Function & Location

Page 34

CB 200 Pellet Stove

R

 

 

 

Reference Materials

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

Component Function & Location

 

When describing the location of a component,

 

 

 

 

 

 

 

 

 

 

it is always AS YOU FACE THE FRONT OF

 

A.11

 

 

 

 

 

 

1. Control Box

 

 

 

 

 

THE APPLIANCE.

 

 

 

a. The control box is located under a small cover in the

 

 

 

 

 

7.

Heat Exchangers

 

 

 

right rear corner of the inside of the hopper.

 

 

 

b. There is a light located inside of the control box. The

The heat exchangers transfer hot air from the exhaust system

 

into convection air. Lift the stove top to access the heat

 

internal light will turn green when the appliance has

 

reached a temperature of 200οF (93°C) in the firepot

exchangers. There are 2 clean out rods located under the

 

and will turn red when it reaches 600oF (315°C).

heat exchangers.

 

 

 

c. There is also an internal blue light located in the upper

8. Heat Output Switch

 

 

 

left corner of the control box.

When you plug in the

The heat output switch is located on the upper right side panel.

 

appliance the blue light will automatically start blinking

The function of the heat ouput switch is to regulate the burn

 

1 blink every 10 seconds for the first 60 seconds and

rates; low, medium, and high settings.

 

then will stop.

 

 

 

 

9.

Igniter

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

The igniter is mounted on the base of the firepot. Combustion

 

Do NOT open the control box. This will void the

 

air travels over the red hot igniter creating super heated air

 

warranty. If you need to plug in or remove the control

 

that ignites the pellets.

 

 

 

box you must first unplug the appliance.

 

 

10. Junction Box And Wiring Harness

 

 

 

 

 

 

 

The junction box is located on the right side of the appliance,

 

2. Convection Blower

 

 

 

 

 

 

 

behind the interior shield. The junction box and wiring harness

 

The convection blower is mounted at the bottom rear of the

are replaced as one component.

 

 

 

 

 

 

 

appliance. There are 2 impellers, one on each side of the

11.

Power Supply

 

 

 

motor. The convection blower pushes heated air through the

The power outlet is located on the back of the appliance,

 

heat exchange system into the room.

 

 

 

 

 

lower right corner. Check the wall receptacle for 120 volt,

 

3. Exhaust Blower

 

 

 

 

 

 

 

 

 

60 Hz (standard current). Make sure the outlet is grounded

 

The exhaust blower is mounted on the lower left side on

and has the correct polarity.

A good surge protector is

 

recommended.

 

 

 

rear of appliance. The exhaust blower is designed to pull

 

 

 

 

 

 

 

 

 

the exhaust from the appliance and push it out through the

12.

Red Call Light

 

 

 

venting system.

 

 

 

 

The red call light is on the front of the junction box, next to the

 

4. Feed System

 

 

 

 

 

 

 

 

 

reset button. The function of the red call light is to indicate

 

The feed system is located in the hopper under the feed

that the thermostat is calling for heat.

 

 

 

 

 

 

 

motor cover box on the left side of the appliance and can

13.

Reset Button

 

 

 

be removed as an entire assembly. The assembly includes

The reset button is located on the right side of the apppliance

 

the feed motor, mounting bracket, bearing and feed spring

 

next to the red call light. The function of the button is to

 

(auger). The hollow feed spring (auger) pulls pellets up the

 

momentarily open the thermostat circuit, which restarts the

 

feed tube from the hopper area and drops them down the

 

system.

 

 

 

feed chute into the firepot.

 

 

 

 

 

 

 

 

 

14.

Thermocouple

 

 

 

5. Firepot

 

 

 

 

 

 

 

 

 

 

 

The thermocouple is located on top of the firepot inside

 

The firepot is made of high quality ductile iron and has a

 

the thermocouple cover (ceramic protection tube). The

 

cleaning pull-out rod. The floor of the firepot opens for

 

thermocouple sends a millivolt signal to the control box

 

cleaning when you pull out the rod. Be sure that the floor

 

indicating the preset temperatures of the green and red lights

 

returns to a completely closed position or your appliance will

 

have been obtained.

 

 

 

not operate properly.

 

 

 

 

 

 

 

 

 

 

 

15.

Thermostat

 

 

 

6. Fuse

 

 

 

 

 

 

 

 

 

 

 

The appliance is designed to run on a 12 volt AC thermostat.

 

The fuse is located on the front of the junction box on the

 

The heat anticipator should be set on the lowest setting

 

right side of the appliance. The fuse will blow should a short

 

available.

 

 

 

occur and shut off power to the appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 34

 

 

7014-082B

September 21, 2006

Image 34
Contents Classic BAY 1200 Pellet Stove CB 1200 Pellet Stove Testing Lab & Report Number Serial Number Model Mfg DateBehind left side curtain on outside of hopper wall Table of Contents Listing and Code Approvals Getting Started Design, Installation & Location ConsiderationsFire Safety Appliance LocationMeasuring Standards CB 1200 Pellet Stove Tools And Supplies NeededInspect Appliance & Components and Pre-Use Check List Dimensions and Clearances Appliance DimensionsCB 1200 Pellet Stove Clearances to Combustibles UL and ULC CB 1200 Pellet Stove Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsHearth Pad Requirements Vent Information CB 1200 Pellet Stove Equivalent Feet of Pipe Pipe Selection ChartLevel of this installation. See Figure Example of 3 Elbow-Rear Vent Termination Calculaton5Venting Systems AlcoveDegree Straight OutCB 1200 Pellet Stove Through The Wall CB 1200 Pellet Stove Vertical Through The Wall & VerticalMasonry Alternate MasonryMobile Home Appliance Set-Up Rear Installation Floor InstallationOutside Air Kit Instructions Rear Vent and Rear Vent to Top Vent Adapter Installation CB 1200 Pellet Stove Top Vent Adapter InstallationInstalling the Top Vent Adapter CB 1200 Pellet Stove Brick Set Installation Brick Clip InstallationLeft Twig Right Twig Installing Logo Nickel OnlyCharred Areas in the Back Front Log Holes. See FigureTo install door Door InstallationCB 1200 Pellet Stove Thermostat Installation To adjust latchesOperating Instructions Fuel Size And Material General Operating InformationFeed Rate Adjustment Instructions Fuel Adjustment RodStarting Your First Fire Frequently Asked Questions CB 1200 Pellet Stove Ignition CyclesSymptom TroubleshootingPossible Cause Corrective Action Page Page Maintaining & Servicing Your Appliance Ash Removal from Firebox Cont’d Cleaning Heat Exchanger ChambersCleaning Beneath Heat Exchanger Disposal of Ashes Frequency As neededCleaning Exhaust Blower Requires No Lubrication Cleaning the Glass Frequency As neededCleaning the Hopper Cleaning Convection Blower Requires No LubricationCB 1200 Pellet Stove High Ash Fuel Content Maintenance Convection Blower ReplacementInstall new blower Exhaust Blower Replacement Remove existing blowerRe-install blower to blower housing Replacing Side Glass Replacing Center GlassScrews CB 200 Pellet Stove Reference MaterialsComponent Function & Location Snap Disc #1 Convection Blower 145F Vacuum SwitchWiring Harness See .1 below Snap Disc #2 Thermostat Override 200FCB 1200 Pellet Stove Component Locations Glass Size Center 13-7/8 wide x 11 high CB 1200 Pellet Stove Exploded ViewsGlass Size Sides Nbr Description CB 1200 Pellet Stove CB 1200 Pellet Stove Service Parts and Accessories Item # Parts Alphabetical OrderAccessories Item # Service Parts Alphabetical OrderAppliance CB 1200 Pellet Stove Service And Maintenance Log Date of Service Performed By Description of ServiceLifetime Warranty CB 1200 Pellet Stove Warranty PolicyContact Information Telephone

CB1200 specifications

The Quadra-Fire CB1200 is a highly efficient and versatile wood-burning stove that stands out in the market for its innovative features and robust performance. With a focus on both functionality and aesthetics, the CB1200 aims to provide a comfortable, efficient heating solution while enhancing the beauty of any living space.

One of the main features of the Quadra-Fire CB1200 is its powerful heating capability. It boasts a maximum heat output of up to 80,000 BTUs, making it suitable for heating large areas within homes and cabins. The unit can efficiently heat spaces up to 2,500 square feet, offering reliable warmth even in the coldest climates. This impressive output is complemented by an extended burn time, allowing for longer periods between refueling, which adds convenience for users.

The CB1200 comes equipped with Quadra-Fire's renowned Advanced Combustion Technology. This cutting-edge system improves the efficiency of the fire by maximizing the combustion of gases and particles, leading to a cleaner burn with reduced emissions. This not only enhances the stove's overall performance but also provides a more environmentally friendly heating solution.

Another notable characteristic of the CB1200 is its user-friendly design. The large, glass door provides an excellent view of the fire, creating a warm and inviting ambiance while ensuring easy monitoring of fuel levels. The stove features a convenient ash pan for effortless cleanup, and the adjustable airflow control allows users to customize the burn intensity to suit their heating needs.

In addition to its performance features, the CB1200 is designed with durability in mind. Constructed from high-quality materials, it is built to withstand the rigors of regular use. The unit also offers various finishing options, enabling homeowners to select a style that complements their décor.

The Quadra-Fire CB1200 combines efficiency, beauty, and convenience, making it an exemplary choice for anyone seeking a wood-burning stove. With its impressive heating capabilities, advanced combustion technology, and user-friendly features, the CB1200 is designed to provide lasting comfort and satisfaction for its users, making it a worthwhile investment for any home.