| | | | | | | Listed by | O-T L | Beaverton | | | | Report Rapport | | | | | | | | | | | | | | | | | | | | | | | | | | | SERIAL NO. NUMÉRO DU | | | | |
| | | | | | | | | | Oregon USA | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | C | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | CB 1200 Pellet Stove | C | | | | | | |
| | | | | | | | OMNI-Test Laboratories, Inc. | | | | | 061-S-21-4 | | | | | | | | | | | | | | | | | | | | | | | | | | | 007 | | | | | | | |
| | | | Installation. This appliance has | | Appareil de chauffage inséré de combustible solide/de | type de boulettes. Accepté dans l'installation | dans les maisons mobiles. Cet |
| Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home | |
| been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909. | | appareil a été testé et enregistré pour l'usage dans les | Maisons Mobiles en accord avec OAR 814-23- | 9000 jusqu'à 814-23-909. | |
| Tested to: ASTM E1509, ORD-C-1482-M1990 Room Heating Pellet Burning Type, APFI, (UM) 84-HUD FOR | | | Testé à: ASTM #1509-95, ORD-C 1482-M1990 | Room Heating. | Pellet Burning Type, | APFI, (UM) 84-HUD POUR |
| USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL. | | | | | | | | | | | | | | | USAGE AVEC LES BOULETTES DE BOIS OU DE COMBUSTIBLE DE MAIS ÉCOSSÉ DES CHAMPS. |
| Input Rating: 40,000 Btu's/hr | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Puissance de Rendement: 40,000 Btu's/hr | | | | | | | | | | |
| Electrical Rating: | 115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS. | | | | | | | | | | | | | | | | | | | | Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps, | | | | | | | | |
| Route power cord away from unit. Do not route cord under or in front of appliance. | | | | | | | | | | | Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. |
| DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm | | | DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service. |
| | | Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur. | | | | | | |
| ceramic | available | from your | dealer. | To start, set | thermostat | above room | temperature, the stove will | light | | | | | | | | |
| | | Pour | allumer, | monter | la température du thermostat au | dessus | de | la température de la | pièce, le poêle s'allumera |
| automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's | | |
| | | automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des |
| manual.Keep viewing and ash removal doors tightly closed during operation. | | | | | | | | | | | | | |
| | | | | | | | | | | | | | instructions supplémentaires, référez vous au manuel du propriétaire. | Gardez la porte d'ouverture et la porte des cendres |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | fermées hermétiquement durant l'opération. | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / | | LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES: |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | ESPACES | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | A | | | | | | C | | | | | | | | D | | | | | | | | | | E | | | C | | | | | A | | | C | A | Back Wall to stove / Mur Arrière du poêle | | | | 2"/51mm |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | B | Side Wall to Cast Top / Mur De Côté du haut | | 6"/152mm |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | CORNER INSTALLATION / NSTALLATION DU COIN : | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | L | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | C | Side Wall / Mur De Côté | | | | | | 2"/51mm |
| | | | | | | | | B | | | | | | | | | | C | | | | | | | | | | B | | | | | | | E | | | | | | | | | | | | B | VERTICAL ADAPTER KIT INSTALLATION: | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | UN ASSEMBLAGE POUR ADAPTEUR POUR INSTALLATION VERTICALE: |
Note 1: In residential installations, | when using | Parts 811-0580, (3" | - | 3" Top | Vent Adapter) and | | | | | | | | | | | | | D | Back Wall to Flue Pipe / Mur Arrière tuyau rigide | | 3"/76mm |
812-2690 (3" - 6" Top Vent Adapter Collar) 24 gauge 6" single wall flue connector may be used. | P | | F | | | | | B | Side Wall to Cast Top / Mur De Côté du haut | | 6"/152mm |
| | | | | CORNER INSTALLATION WITH VERTICAL ADAPTER KIT: | | | | | | |
Note 1: Dans les installations résidentielles, lorsque les pièces 811-0580, (dessus de l'adapteur de | | | | | | | | | | | D | INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL: |
ventilation 3" - 3") et 812-2690 (collier de l'adapteur de ventilation 3" - 6"), un tuyau connecteur de 6" | | | | | | | | | | | | | E | Side Wall / Mur De Côté | | | | | | 2"/51mm |
pour mur simple de calibre 24 peut être utilisé. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | ALCOVE INSTALLATION / INSTALLATION DE L' ALCÔVE: | | | | | | |
Note 2: In manufactured home installation, when using Part 811-0580, (3" - 3" Top Vent Adapter) and | | | | | | | | | | | A | Max. Alcove Depth: / La profondeur maximum de l'alcôve | | 36"/914mm |
| | | | | | | | | | A | Back Wall to stove / Mur Arrière du poêle | | | | 2"/51mm |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | M | | | | | | | | | | | | | | | | | | | | | | | | | |
812-2690 (3' - 6" Top Vent Adapter Collar), use listed double wall flue connector. | An Outside Air Kit | | | | | | | | | | | | | B | Side Wall to Cast Top / Mur De Côté du haut | | 6"/152mm |
(Part 811-0560 rear or 811-0570 floor), must be used with manufactured home installation. | | | | | | | | | | | | | | | C | Unit corner to diagonal wall / | | | | | | 2" (51mm) |
Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces 811-0580 (dessus de | | | | | | | | | | | | | F | Top of Unit to Combustibles / Du poêle du haut combustibles | | 12.5"/318mm |
| | | | | | | | | | | | | | | | | | | | | | | | |
l'adapteur de ventilation 3" - 3") et 812-2690 (collier de l'adapteurAde ventilation 3" - 6"), utilisez un | | | | | | | | | | | | | | Alcove vertical installation / Installation verticale de l'alcôve |
tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0560 arrière | | | | | | | | | | | | | D | Back Wall to Flue Pipe / Mur Arrière tuyau rigide | | 3"/76mm |
au 811-0570 la plancer), doit être utilisé pour l'installation dans les maisons préfabriquées. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | FLOOR PROTECTION / PROTECTION DU SOL | | | | | | | | | | |
| | | | | | | H* | | *Non-combustible floor protection must extend beneath the flue pipe when installed with | *Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une |
| | | | | | | | | | | | | | | | | | | | | | S | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | horizontal venting or under the Top Vent Adapter with vertical | | installation. | installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une |
| | G | | | | | | G | |
| | | | | | | | | | | RECOMMENDED IN USA; REQUIRED IN CANADA | | | | | | | | | | | | | | | | | | installation verticale. ÉTATS-UNIS - RECOMMANDÉ; CANADA - REQUIRENT |
| | | | | | | I | | Floor protector must be noncombustible material, extending beneath heater and to the | Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les |
| G = 2"/51mm | | front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door. | schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée. | |
| H* = 2"/51mm | | | | | | | | | | | | | U.S. ENVIRONMENTAL PROTECTION AGENCY This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"]. |
| I = 6"/152mm | | | 1445 Highway North | | 2006 | | 2007 | | 2008 | | JAN | FEB | MAR | | APR | MAY | JUNE JULY AUG | SEPT | OCT NOV | DEC | | | | | |
| | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | Colville, WA 99114 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | www.quadrafire.com | DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE | | | Made in China/Fait Aux Chine | | | | | | 250-3182 | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |