4300 ACT Wood Stove Series
SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE
For the method of installation to a masonry chimney shown in Figures 14A & 14B on page 14, it will be necessary to purchase a 12” (305mm) long 8" (203mm) inside diameter, section of prefabricated listed solid pack chimney to use as a thimble. Purchase a wall spacer, trim collar, and a wall band manufactured to fit the chimney section you purchase.
The safety features of this system are twofold: 1) A 2" (51 mm) air space between the chimney section and combustible wall; and, 2) The 1" (25mm) air space around the chimney connector as it passes through the chimney section to the chimney.
The location of the opening through the wall to the chimney must leave a minimum 18" (457mm) vertical clearance between the connector pipe and the ceiling (or minimum recommended from pipe manufacturer) to prevent the ceiling from catching fire.
Measure for the
CONCRETE CAP | FIRECLAY FLUE |
LINER WITH AIR | |
| SPACE |
Wall
Opening | Center of Hole |
Center Line
RAFTER
1" (25mm) CLEARANCE WITH FIRESTOP
FLASHING
Center Line
Add
FIGURE 12A
CEILING | EAVE | |
JOIST | ||
| ||
COMBUSTIBLE |
| |
WALL | 1" (25mm) | |
| CLEARANCE | |
THIMBLE, |
| |
12" (305mm) |
| |
OF BRICK | SHEATHING | |
|
FLOOR
PROTECTOR
FIGURE 12B | AIRTIGHT |
| CLEANOUT DOOR |
WARNING! ALWAYS FOLLOW CHIMNEY CONNECTOR MANUFACTURER’S INSTRUCTIONS FOR PROPER INSTALLATION.
CHIMNEY CONNECTOR IS TO BE USED ONLY WITHIN THE ROOM, BETWEEN THE STOVE AND CEILING OR WALL, NEVER PASSING THROUGH A COMBUSTIBLE CEILING OR WALL. THE CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR, OR CEILING. MAINTAIN MINIMUM CLEARANCES TO COMBUSTIBLES AS REFERENCED ON PAGE 7.