12 Operating Instructions

A. Before Lighting Appliance

This appliance has a Standing Pilot Ignition.

Before operating this appliance have a qualified technician:

Remove all shipping materials from inside and/or underneath the firebox.

Review proper placement of logs, rockwool, lava rock, and vermiculite.

Check the wiring.

Check the air shutter adjustment.

Purge gas line (with glass assembly removed). See Section 8.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position.

Ensure that the flow of combustion and ventilation air is not obstructed (front grilles and vent caps).

WARNING

Fire Risk.

Explosion Risk.

Gas may build up while lighting pilot.

Remove glass assembly before lighting pilot.

Replace glass assembly after lighting pilot.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Quadra-FireQVI-25FB-S2031-910 Rev. D • 3/08

25

Image 25
Contents What to do if you smell gas ModelHOT Surfaces Xxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededMinimum Fireplace Opening Fireplace Size RequirementsClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsVent Table Key Vent Information and DiagramsHorizontal Venting Measuring StandardsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Locking TAB Handle Placing, Securing and Leveling the Appliance Masonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversions Gas Connection Gas InformationGas Pressures Check for GAS Leaks High Altitude InstallationsON/OFF Switch Wiring the ApplianceElectrical Information Appliance RequirementsInstallation for Fan Optional Junction Box InstallationOptional Accessories Fan Wiring Diagram Mantel Projections FinishingClean the Appliance Appliance SetupAccessories Ember PlacementLog Placement Log Set Assembly LOGS-2031Positioning the Logs Quadra-Fire QVI-25FB-S 2031-910 Rev. D 3/08 Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceWhat to do if YOU Smell GAS Pilot Adjustment Initial Break-in ProcedureCheck Pilot Flame Appearance After Appliance is LitIssue Solutions Frequently Asked QuestionsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksQVI-25FB-S Model Dimensions Appliance Dimension DiagramReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsService Parts List Log Set Assembly119 1312 Part number list on followingStocked Service PartsAt Depot Valve Assembly Limited Lifetime Warranty Lifetime WarrantyContact Information