7 Installing Vent Pipe and Appliance
A. Venting Components
CAUTION
Sharp Edges
•Wear protective gloves and safety glasses during installation.
The vertical vent termination system installed on this model includes:
•One
•One length of
•Flexible vent pipe for exhaust air (included with vent kit).
•One
•One vertical termination cap (included with vent kit).
B. Connecting Vent Pipe
Reference instructions in the termination kit.
•Install the
•Secure the exhaust flexible vent pipe to the 3 foot section stainless steel flexible vent pipe using the factory- installed
•Use 3 screws to attach either a 4 foot or 30 foot section of inlet air vent to the inlet collar on the collar slide plate (see Figure 7.1). NOTE: The collar slide plate may be removed from appliance to aid installation.
•Seal opening between flex vent and chimney just above insert. Unfaced fiberglass insulation may be used for this purpose.
11 |