11 Appliance Setup

A. Remove Shipping Materials

Remove shipping materials from inside or underneath the firebox.

Placing the Ember Material

Ember material is shipped with this gas appliance. To place the ember material:

• Embers CANNOT be placed directly over ports.

B. Clean the Appliance

Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity.

C. Accessories

Install approved accessories per instructions included with accessories. See Service Parts List for appropriate accessories.

WARNING

Shock or fire risk.

Use ONLY optional accessories approved for this appliance.

Using non-listed accessories voids warranty.

Using non-listed accessories may result in a safety hazard.

Only Hearth & Home Technologies approved

accessories may be used safely.

When placing Glowing Embers® onto the burner care should be taken so that the ports are not covered. Place the dime-size ember pieces near port holes in burner top, sides and front (see Figure 11.1). Failure to follow this procedure will likely cause lighting and sooting problems.

BURNER PAN

EMBER

PLACEMENT

Figure 11.1 Placement of Embers

D. Ember Placement

WARNING

Explosion Risk.

Follow ember placement instructions in manual.

Do NOT place embers directly over burner ports.

Replace ember material annually.

Improperly placed embers interferes with proper burner operation.

Place Mystic Ember over burner surface and around base of burner. Do not cover any burner port holes. Use this material to give the appliance a realistic ash bed.

Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications.

Quadra-FireQVI-25FB-S2031-910 Rev. D • 3/08

21

Image 21
Contents Model What to do if you smell gasHOT Surfaces Xxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededMinimum Fireplace Opening Fireplace Size RequirementsClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsVent Table Key Vent Information and DiagramsHorizontal Venting Measuring StandardsInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Locking TAB Handle Placing, Securing and Leveling the Appliance Masonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalGas Information Fuel Conversions Gas ConnectionGas Pressures Check for GAS Leaks High Altitude InstallationsON/OFF Switch Wiring the ApplianceElectrical Information Appliance Requirements Junction Box Installation Installation for Fan Optional Optional Accessories Fan Wiring Diagram Mantel Projections FinishingClean the Appliance Appliance SetupAccessories Ember PlacementLog Set Assembly LOGS-2031 Log PlacementPositioning the Logs Quadra-Fire QVI-25FB-S 2031-910 Rev. D 3/08 Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Lighting Appliance Standing Pilot IgnitionWhat to do if YOU Smell GAS Pilot Adjustment Initial Break-in ProcedureCheck Pilot Flame Appearance After Appliance is LitIssue Solutions Frequently Asked QuestionsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram QVI-25FB-S Model DimensionsReference Materials Direct Vent Flex Liner Kits Vent Kits ComponentsService Parts List Log Set Assembly119 1312 Part number list on followingService Parts StockedAt Depot Valve Assembly Limited Lifetime Warranty Lifetime WarrantyContact Information