1 Listing and Code Approvals
A. Appliance Certification
MODELS: QVI-25FB-S
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Appliance Heaters
STANDARD: ANSI
This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.
Note: To assure top performance, safety and efficiency, inserts must be installed with an approved flue liner as per CAN/CGA
Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI
B. BTU Specifications
Models |
| Maximum | Minimum | Orifice | |
| Input | Input | Size | ||
(U.S. or Canada) | BTU/h | BTU/h | (DMS) | ||
|
|
|
|
|
|
|
| US | 29,650 | 21,000 | #36 |
| |||||
|
|
|
| ||
| CANADA | 26,600 | 18,900 | #37 | |
|
| ||||
|
| ||||
|
|
|
|
|
|
|
| US | 27,000 | 16,000 | #52 |
| |||||
|
|
|
| ||
| CANADA | 24,300 | 14,400 | #53 | |
|
| ||||
|
| ||||
|
|
|
|
|
|
C. High Altitude Installations
U.L. Listed gas appliances are tested and approved with- out requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.
When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rat- ing by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A., or 10% for elevations between 2000 and 4500 feet in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.
WARNING
Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
D. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750º C, shall be considered
E. Combustible Materials Specification
Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ig- nite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials.
4 |