5 Vent Information and Diagrams
A. Vent Table Key
The abbreviations listed in this vent table key are used in the vent diagrams.
Symbol | Description |
VMIN | Minimum Vertical Run Length 14 ft. |
VMAX | Maximum Vertical Run Length 50 ft. |
B. Horizontal Venting
Horizontal venting is NOT allowed.
C. Measuring Standards
Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:
• Vertical terminations are measured to top of chimney.
WARNING
Fire Hazard. Explosion Risk. Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.
•May impair safe operation of this appliance or other appliances connected to the flue.
•Vent this appliance directly outside.
•Use separate vent system for this appliance.
CAUTION
ALL vent specifications MUST be followed.
•This product is tested and listed to these specifications.
•Appliance performance will suffer if specifications are not followed.
TERMINATION |
|
CAP |
|
FLASHING |
|
INLET AIR COLLAR |
|
EXHAUST COLLAR |
|
EXHAUST |
|
VENT PIPE |
|
V= 14 FT. MINIMUM |
|
50FT. MAXIMUM |
|
3 INCH COLLAR |
|
(Factory installed to |
|
stainless steel section) |
|
WARNING: DO NOT |
|
BLOCK PIPE END WITH |
|
INSULATION OR ANY OTHER |
|
SEALING MATERIAL |
|
STAINLESS STEEL |
|
PIPE - 3 FT. MIN. |
|
REQUIRED (INCLUDED) |
|
SEAL DAMPER |
|
AREA |
|
INLET AIR |
|
VENT PIPE |
|
COLLAR ATTACHMENT |
|
BRACKET |
|
Figure 5.1 |
|
9 |