Samsung AQ07XANSEU, AQ07XAXSEU, AQ09XANSER, AQ07XANSER, AQ07XAXSER Connecting the Assembly Cable

Page 8

INSTALLING THE AIR CONDITIONER

Connecting the Assembly Cable

Indoor Unit

N 1

1

2

3

E

N1

N1

2

3

E

N1

1

2

3

Outdoor Unit

N 1

1

2

3

**Screws on terminal block must not be unscrewed with the torque less than 12 kgf.cm.

The designs and shape are subject to change according to the model.

The outdoor unit is powered from the indoor unit through the assembly cable. If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15 meters.

1Extend the assembly cable if necessary. .

2Remove the cover terminal on the side of the indoor unit.

3Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals as seen in the picture.

Each wire is labeled with the corresponding terminal number.

4Pass the other end of the cable through the 65mm hole in the wall.

5Close the connector cover tightening the screw carefully.

6Close the cover terminal.

7Remove the terminal board cover on the side of the outdoor unit.

8Connect the cables to the terminals as seen in the picture.

Each wire is labeled with the corresponding terminal number.

9Connect the earth conductor to the earth terminals.

10Close the terminal board cover tightening the screw carefully.

Specially for Russian and European market, Before installation, the supply authorithy should be consulted to determine the supply system impedance to ensure compliance.

Power cable specification

Model

Power cable

Interconnection cable

 

 

 

**07**

-

5G, 0.75mm2

H05VV-F

 

 

**09**

-

5G, 1.0mm2

H05VV-F

 

 

 

 

 

Connect the power cable to the auxiliary circuit breaker If every pole fails to connect to the power supply, it must be incorporated in a wire with a contact opening of >3mm.

E-8

Image 8
Contents Installation Manual Safety Precautions Contents Deciding on Where to Install the Air Conditioner Indoor UnitMm minimum Accessories in the Outdoor Unit Case Air Conditioner and AccessoriesAccessories in the Indoor Unit Case Fixing the Installation Plate Purging the UnitThen follow Steps Wall Window frameConnecting the Assembly Cable Installing and Connecting the Indoor Unit Drain Hose Installing and Connecting the Outdoor Unit Drain HoseInstalling and Connecting the Indoor Unit Assembly Piping Torque kgf cmCutting/Extending the Piping 35 mm 52 mmConnecting Up and Purging the Circuit Outer Diameter Torque kgfcmPlacing the Indoor Unit in Position To check for gas leaks on Then, using a leak detector CheckPerforming Leak Tests Checking and Testing Operations Fixing the Outdoor Unit in PositionExplaining Operations to the Owner Electronics ÊìäéÇéÑëíÇé èé ìëíÄçéÇäÖ ÅÂ˚ è‰ÓÒÚÓÓÊÌÓÒÚË ËÓ‰ÂʇÌË ˚·Ó ÏÂÒÚ‡ ‰Îfl ÛÒÚ‡ÌÓ‚ÍË ÍÓ̉ˈËÓÌÂ‡ ÄÓÏ̇ÚÌ˚È ·ÎÓÍ300 ÏÏ ËÎË ·ÓΠ125 ÏÏ ËÎË ·ÓΠÄÓ̉ˈËÓÌÂ Ë ÔË̇‰ÎÂÊÌÓÒÚË Í Ìâïû Ë̇‰ÎÂÊÌÓÒÚË, ÛÔ‡ÍÓ‚‡ÌÌ˚ ‚ ÍÓÓ·ÍÛ ÍÓÏ̇ÚÌÓ„Ó ·ÎÓ͇ÅÓÌÚ‡Ê ÛÒÚ‡ÌÓ‚Ó˜ÌÓÈ Ô·ÒÚËÌ˚ ‰‡ÎÂÌË „‡Á‡ ËÁ ·ÎÓ͇ÈÓ‰Íβ˜ÂÌË ÒÓ‰ËÌËÚÂθÌÓ„Ó Í‡·ÂÎfl ‡‡ÍÚÂËÒÚËÍË Í‡·ÂÎfl ÔËÚ‡ÌËflÅÓÌÚ‡Ê Ë ÔÓ‰ÒÓ‰ËÌÂÌË ‰Â̇ÊÌÓ„Ó ¯Î‡Ì„‡ Í ÍÓÏ̇ÚÌÓÏÛ ·ÎÓÍÛ ÌÒÚ‡Ìӂ͇ Ë èÓ‰ÒÓ‰ËÌÂÌË ÑÂ̇ÊÌÓ„Ó ò·̄‡ äÓÏ̇ÚÌÓ„Ó ÅÎÓ͇ÅÓÌÚ‡Ê Ë ÔÓ‰ÒÓ‰ËÌÂÌË ÚÛ·ÓÔÓ‚Ó‰‡ Í ÍÓÏ̇ÚÌÓÏÛ ·ÎÓÍÛ ÂʸÚ ËÁÎ˯ÍË ÔÂÌÓÂÁËÌÓ‚ÓÈ ËÁÓÎflˆËËÊÂÁ͇ ÚÛ·ÓÍ/ ì‰ÎËÌÂÌË ÚÛ·ÓÔÓ‚Ó‰‡ ‰ÎËÌÂÌÈÓ‰ÒÓ‰ËÌÂÌË ÚÛ·ÓÔÓ‚Ó‰‡ Ë Û‰‡ÎÂÌË ËÁ ÌÂ„Ó ‚ÓÁ‰Ûı‡ ÏóïâìúóÓ‚Â͇ ÓÚÒÛÚÒÚ‚Ëfl ÛÚ˜ÍË „‡Á‡ ÌÒÚ‡Ìӂ͇ ÍÓÏ̇ÚÌÓ„Ó ·ÎÓ͇ ‚ Ìûêìóï Ôóîóêâìëë‡ÍÂÔÎÂÌË ç‡ÛÊÌÓ„Ó ÅÎÓ͇ Ó‚ÂÍË Ë ÔÓ·Ì˚È ÔûòíÀÌÒÚÛÍÚ‡Ê ÔÓθÁÓ‚‡ÚÂÎfl AQ07X*RIM27212 1/19/07 1121 AM