Monessen Hearth MJ27PR, MJ27NR Fireplace Preparation, Before installing in a solid fuel burning

Page 17

FIREPLACE PREPARATION

Before fully installing the unit:

Turn OFF the gas supply to the fireplace or firebox.

Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.

 

warning

Before installing in a solid fuel burning

 

 

 

 

 

fireplace, The chimney flue and firebox must

 

 

be cleaned of soot, creosote, ashes and loose

 

 

paint by a qualified chimney cleaner.

 

 

 

 

 

 

INSTALLING VENTED APPLICATIONS

Manual and Millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 and National Fuel Gas Code, Section 6.6. Since, the gas logs are operated with the damper open, non-combustible material and minimum mantel requirements do not apply.

WARNING

This appliance is for installation only in a solid fuel burning fireplace (masonry fireplace or manufactured fireplace) with a working flue and constructed of noncombustible material.

Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating that it has not been tested or should not be used with unvented gas logs. This log set may be installed as a vented log set.

Before installing the appliance:

Turn off gas supply to fireplace or firebox.

Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other obstruc- tions. Have this cleaning performed annually after installation.

Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant

sealant.

Install and operate the appliance as directed in this manual.

Damper stop installation:

A damper stop must be provided with the unit. Contact your dealer to obtain one. The damper stop must be installed as shown in Figure 12 to prevent full closure of the fireplace damper blade and provide a minimum 29 square inch flue opening.

Damper Stop

Damper

FP2005

Figure 12 - Damper Stop Installation.

WARNING

The fireplace and gas logs function as a system. If the fireplace is spilling into the room (check with a match or a smoke stick), reposition the damper clamp until a positive draft is obtained by opening the damper. If negative pressure in home prevents having a positive draft, contact your dealer for assistance.

86D0024

17

Image 17
Contents Natural Gas or Liquid Propane Control Type Millivolt Hi/Low Models MJ27NR, MJ27PRContents Installer Important Safety InformationOwner Gas Code, Ansi Z223.l/NFPA54Known as wellhead gas Never connect unit to private nonUtility gas wells. This gas is commonly Make sure you have received all parts What you will need for installationGetting Started Product Features and Specifications Codes General Installation InformationAmerican National Standards Institute, Inc National Fire Protection Association, IncBTU / hr = Minimum Hearth Dimension Fireplace and Hearth DimensionsHeight of Restriction Minimum Depth of Fireplace/Firebox Placement in a fireplace with a restrictive barrierSidewall and Ceiling Clearances Clearances and Height RequirementsMeasurement MJ27 Requirements for Safe InstallationHeat Resistant Mantel, Shelf or Other Combustible Projection Heat Resistant Requirements for Safe Installation with Wood12 min Is an example of an unsafe mantel instal Minimum Clearance above Combustible Flooring Floor ClearancePaint by a qualified chimney cleaner Before installing in a solid fuel burningInstalling Vented Applications Fireplace PreparationPlacing and Securing Appliance Installing Vented ApplicationsAssembly procedure Gas Connection Connecting the GASMillivolt Valve Control Figure Checking GAS PressureAte Electrical Wiring MillivoltDo not allow wires Connecting Remote ReceiverBurner To touch grate orLOG Placement Install Log #8 Install Log #4 Place Flickering Bright Embers Place Flickering EmbersANDIRON Installation Andiron and rock installationAssembly Instructions Placing the decorative rockChecking the pilot flame Flame AppearanceOperating Instructions Checking the Burner FlameWhat to do if YOU Smell GAS Operating InstructionsTo Turn OFF GAS to Heater Cleaning and Servicing Operating Instructions / Cleaning and ServicingServicing. Only a qualified service person TroubleshootingShould service and repair the heater Turn appliance OFF and allow to cool beforeGoes out when control Description Qty Replacement partsDescription Qty MJ27 Replacement Parts listLogs Please Read and Follow These 86D0024 Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededMhsc