CHECKING THE BURNER FLAME
In normal operation at full rate after 15 minutes, the following flame appearances should be observed:
LG551
Figure 33 - Correct Burner Flame Appearance
Burner will have a random pattern of yellow flames as shown in Figure 33. There should be glow- ing embers on the front burner. Note: The front flames and embers will be an opaque orange color during the burn off time.
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the fireplace. Do not place a blower inside the burn area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.
The initial
This appliance must not be used with glass doors in the closed position. This can lead to pilot out- ages and severe sooting outside the fireplace. Refer to Page 10, Figure 3.
86D0024 | 29 |